Error messages if the order cannot be executed, 2 sub-index (ind), Sub-index (ind) – NORD Drivesystems BU0020 User Manual
Page 86
PROFIBUS DP
– Supplementary manual options for NORD - Frequency Inverters
86
BU 0020 GB-2612
Error messages if the order cannot be executed
In the response label "Order cannot be executed" (AK = 7), then an error message is added to the
parameter value (PWE2) of the inverter response. For the meanings of the values transferred, please
refer to the following table.
AK
Meaning
0
Invalid parameter number
1
Parameter value cannot be changed
2
Lower or upper value limit exceeded
3
Incorrect sub-index
4
No array
5
Invalid data type (at present only for SK 700E)
6
Only resettable (only 0 may be written)
7
Description element cannot be changed
9
Description data not present
201
Invalid order element in the last order received
202
Internal response label cannot be depicted
Pos: 137 /Anleitungen/Bussysteme/6. Datenübertragung/Profibus [BU0020]Subindex (IND) @ 1\mod_1336395654694_388.docx @ 25711 @ 3 @ 1
7.5.2 Sub-index (IND)
1
2
3
4
PKE
IND
PWE1
PWE2
15
14 13
12 11
10 9
8
7
6
5
4
3
2
1
0
P1-P4
No information / all 0
Array 1-64
P1-P4
Sub-index
The structure and function of the parameter index (IND) depends on the type of parameter to be
transferred. For values which depend on the parameter set, the parameter set can be selected via Bits
8 and 9 of the Index (IND) (0 = parameter set 1, 1 = parameter set 2,...).