6 parameterisation, P544 bus actual value 2, P545 bus actual value 3 – NORD Drivesystems BU0020 User Manual
Page 65: P546 func. bus-set point 1
6 Parameterisation
BU 0020 GB-2612
65
0 =
Off
13 = ... 16 Reserved
1 =
Actual frequency
17 = Value analog input 1
2 =
Actual speed
18 = Value analog input 2
3 =
Current
19 = Setpoint frequency master
value(P503)
4 =
Torque current (100% = P112)
20 = Setpoint frequency master value after
ramp "Setpoint frequency master
value after ramp"
5 =
Digital IO status
7
21 = Act. freq. without slip master value
"Actual frequency without slip master
value"
6 =
... 7 Reserved
22 = Speed encoder (only possible with
SK 520E and encoder feedback)
8 =
Setpoint frequency
23 = Actual frequency with slip, "Actual
frequency with slip"
(SW V2.0 and above)
9 =
Error number
24 = Master value, actual freq. with slip,
"Master value, actual freq. with slip"
(SW V2.0 and above)
10 = ... 11 Reserved
53 = ... 57 Reserved
12 = BusIO Out Bits 0...7
Further functions are listed in the corresponding supplementary instructions (BU0510 for
POSICON, BU550 for PLC).
Pos: 106 /Anleitungen/5. Parametrierung/Parameter/P500-P599/Parameter P544
– Bus-Istwert 2 [bis SK 535E] @ 0\mod_1328097766412_388.docx @ 11870 @ @ 1
P544
Bus actual value 2
(Actual bus value 2)
up to SK 535E
S
P
0 ... 24
{ 0 }
This parameter is identical to P543.
Condition is PPO 2 or PPO 4 type (P507).
Pos: 107 /Anleitungen/5. Parametrierung/Parameter/P500-P599/Parameter P545
– Bus-Istwert 3 [bis SK 535E] @ 0\mod_1328097880052_388.docx @ 11893 @ @ 1
P545
Bus actual value 3
(Actual bus value 3)
up to SK 535E
S
P
0 ... 24
{ 0 }
This parameter is identical to P543.
Condition is PPO 2 or PPO 4 type (P507).
Pos: 108 /Anleitungen/5. Parametrierung/Parameter/P500-P599/Parameter P546
– Funktion Bus-Sollwert 1 [bis SK 535E] @ 0\mod_1328097962990_388.docx @ 11916 @ @ 1
P546
Func. bus-set point 1
(Function of bus - setpoint 1)
up to SK 535E
S
P
0 ... 55
{ 1 }
In this parameter, a function is allocated to the output setpoint 1 during bus actuation.
The possible analog functions can be found in the following table.
NOTE:
Further details can be found in the respective BUS operating instructions or in the
description of P400.
Pos: 109 /Anleitungen/5. Parametrierung/Parameter/P500-P599/Parameter P546
– Funktion Bus-Sollwerte [ab SK 540E] @ 0\mod_1328098077630_388.docx @ 11939 @ @ 1
7
The assignment of the digital inputs in P543/ 544/ 545 = 5
Bit 0 = DigIn 1
Bit 1 = DigIn 2
Bit 2 = DigIn 3
Bit 3 = DigIn 4
Bit 4 = DigIn 5
Bit 5 = DigIn 6 (SK 520E and above) Bit 6 = DigIn 7 (SK 520E and above)
Bit 7 = Dig. func. AIN1
Bit 8 = Dig. func. AIN1 AIN2
Bit 9 = DigIn 8 (SK 540E and above)
Bit 10 = DigIn 1, 1.IOE (SK 540E and above)
Bit 11 = DigIn 2, 1.IOE (SK 540E and above)
Bit 12 = Out 1/ MFR1
Bit 13 = Out 2/ MFR2
Bit 14 = Out 3/ DOUT1 (SK 520E and above)
Bit 15 = Out 4/ DOUT2 (SK 520E and above)