P546 bus setpoint 1, P547 bus setpoint 2, P548 bus setpoint 3 – NORD Drivesystems BU0020 User Manual
Page 58
PROFIBUS DP
– Supplementary manual options for NORD - Frequency Inverters
58
BU 0020 GB-2612
P546
Bus setpoint 1
(Bus setpoint 1)
SK 300E /
SK 7x0E
S
P
0 ... 7
{ 1 }
In this parameter, a function is allocated to the output setpoint 1 during bus actuation. The
settings 2 to 6 are only relevant for type SK 700E and SK 750E inverters in combination with the
POSICON option.
0 = Off
1 = Setpoint frequency (16 bit)
2 = 16 Bit setpoint position
3 = 32 Bit Bit setpoint position (PPO
type 2 or 4)
4 = POSICON control terminals (16 Bit)
6
5 = Setpoint position (16 Bit)
6 = Setpoint position (32 Bit) increment
7 = Bus I/O In Bits 0-7
Pos: 83 /Anleitungen/5. Parametrierung/Parameter/P500-P599/Parameter P547
– Bus-Sollwert 2 [SK 300E, SK 7x0E] @ 1\mod_1335788467112_388.docx @ 24976 @ @ 1
P547
Bus setpoint 2
(Bus setpoint 2)
SK 300E /
SK 7x0E
S
P
0 ... 20
{ 0 }
In this parameter, a function is allocated to the setpoint 2 which is output during bus actuation.
0 = Off
11 = Torque precontrol (only SK 7x0E)
(P214)
1 = Setpoint frequency
12 = POSICON control terminals (only
SK 7x0E)
2 = Torque current limit (P112)
13 = Multiplication (only SK 7x0E)
3 = Actual frequency PID
14 = Process controller actual value
4 = Frequency addition
15 = Process controller setpoint
5 = Frequency subtraction
16 = Process controller lead
6 = Current limit (only SK 7x0E) (P536)
17 = BusIO In Bits 0...7
7 = Maximum frequency (only SK 7x0E)
(P105)
18 = Curve
travel
calculator
(only
SK 7x0E)
8 = Actual PID frequency limited
19 = Set relays (P541)
9 = Actual PID frequency monitored
20 =
Set analog output (P542)
10 =
Torque
Pos: 84 /Anleitungen/5. Parametrierung/Parameter/P500-P599/Parameter P548
– Bus-Sollwert 3 [SK 300E, SK 7x0E] @ 1\mod_1335790742656_388.docx @ 25000 @ @ 1
P548
Bus setpoint 3
(Bus setpoint 3)
SK 300E /
SK 7x0E
S
P
0 ... 20
{ 0 }
In this parameter, a function is assigned to the delivered setpoint 3 (SW3) for bus control. This is
identical to parameter P547 and is only present if P546 ≠ 3 and 6.
Pos: 85 /Anleitungen/5. Parametrierung/5.8 Informationen @ 0\mod_1328170311705_388.docx @ 12293 @ 3 @ 1
6
The "reference run", "teach-in" and "reset position can be controlled via the other bits:
Bit 0:
Position array / Position increment
Bit 1:
Position array / Position increment
Bit 2:
Position array / Position increment
Bit 3:
Position array / Position increment
Bit 4:
Position array / Position increment
Bit 5:
Position array / Position increment
Bit 6:
Approach reference point
Bit 7:
Reference point
Bit 8:
Teach- In
Bit 9:
Quit Teach- In
Bit 10:
Reset position