P510, Setpoint source, P513 telegram time-out – NORD Drivesystems BU0020 User Manual
Page 64: P543 bus actual value 1, P543, Bus actual value
PROFIBUS DP
– Supplementary manual options for NORD - Frequency Inverters
64
BU 0020 GB-2612
P510
[-01]
[-02]
Setpoint source
(Setpoint source)
S
0 ... 10
{ all 0 }
Selection of the setpoint source to be parameterised.
[-01] = Main setpoint source
[-02] = Auxiliary setpoint source
Selection of the interface via which the FI receives the setpoint.
0 = Auto (=P509): The source of the auxiliary setpoint is
automatically derived from the setting in the parameter
P509 >Interface<
1 = Control terminals, digital and analog inputs control
the frequency, including fixed frequencies
2 = USS (or Modbus RTU SK 540E and above)
3 = CAN
4 = Profibus
5 = InterBus
6 = CANopen
7 = DeviceNet
8 = Ethernet TU
9 = CAN Broadcast
10 = CANopen Broadcast
Pos: 103 /Anleitungen/5. Parametrierung/Parameter/P500-P599/Parameter P513
– Telegrammausfallzeit @ 0\mod_1328092407709_388.docx @ 11180 @ @ 1
P513
Telegram time-out
(Telegram time out)
S
-0.1 / 0.0 /
0.1 ... 1000 s
{ 0.0 }
Monitoring function of the active bus interface. Following receipt of a valid telegram, the next one
must arrive within the set period. Otherwise the FI reports an error and switches off with the error
message E010 >Bus Time Out<.
0.0 = Off: Monitoring is switched off.
-0.1 = No error: Even if communication between BusBox and FI is interrupted (e.g. 24V error,
Box removed, etc.), the FI will continue to operate unchanged.
Pos: 104 /Anleitungen/5. Parametrierung/Parameter/P500-P599/Parameter P543
– Bus-Istwert 1 [bis SK 535E] @ 0\mod_1328097541755_388.docx @ 11824 @ @ 1
P543
Bus actual value 1
(Actual bus value 1)
up to SK 535E
S
P
0 ... 24
{ 1 }
The return value 1 can be selected for bus actuation in this parameter.
The possible analog functions can be found in the following table.
NOTE:
Further details can be found in the respective BUS operating instructions or in the
description of P418.
Pos: 105 /Anleitungen/5. Parametrierung/Parameter/P500-P599/Parameter P543
– Bus-Istwerte [ab SK 540E] @ 0\mod_1328097636349_388.docx @ 11847 @ @ 1
P543
[-01]
...
[-05]
Bus actual value
(Actual bus values)
SK 540E and
above
S
P
0 ... 57
{ [-01] = 1 }
{ [-02] = 4 }
{ [-03] = 9 }
{ [-04] = 0 }
{ [-05] = 0 }
In this parameter the return value for bus actuation can be selected.
NOTE:
The actual values 4 and 5 must be supported by the relevant bus module. Further
details can be found in the respective BUS operating instructions or in the
description of P418.
[-01] = Bus - Actual value 1
[-02] = Bus - Actual value 2
[-03] = Bus - Actual value 3
[-04] = Bus - Actual value 4
[-05] = Bus - Actual value 5