P546, Function bus setpoint, P547 func. bus-set point 2 – NORD Drivesystems BU0020 User Manual
Page 66: P548 func. bus-set point 3
PROFIBUS DP
– Supplementary manual options for NORD - Frequency Inverters
66
BU 0020 GB-2612
P546
[-01]
...
[-05]
Function Bus setpoint
(Function bus - setpoints)
SK 540E and
above
S
P
0 ... 57
{ [-01] = 1 }
all other { 0 }
In this parameter, during bus actuation a function is allocated to the setpoint provided.
NOTE:
The setpoints 4 and 5 must be supported by the relevant bus module. Further
details can be found in the respective BUS operating instructions or in the
description of P400.
[-01] = Bus setpoint 1
[-02] = Bus setpoint 2
[-03] = Bus setpoint 3
[-04] = Bus setpoint 4
[-05] = Bus setpoint 5
0 =
Off
16 = Process controller lead
1 =
Setpoint frequency
17 = BusIO In Bits 0...7
2 =
Torque current limit (P112)
18 = Curve travel calculator
3 =
Actual frequency PID
19 = Set relays, "Output status"
(P434/441/450/455=38)
4 =
Frequency addition
20 = Set analog output (P418=31)
5 =
Frequency subtraction
21 = ... 45 reserved from SK 530E and above
BU 0510
6 =
Current limit (P536)
46 = Setval.torque p.reg., "Setpoint torque
process controller"
7 =
Maximum frequency (P105)
47 = reserved from SK 530E and above
BU
0510
8 =
Actual PID frequency limited
48 = Motor temperature (SK 540E and above)
9 =
Actual PID frequency monitored
49 = reserved from SK 540E and above
BU
0510
10 = Torque servo mode (P300)
53 = d-correction F process (SK 540E and
above)
11 = Torque precontrol (P214)
54 = d-correction Torque (SK 540E and above)
12 = Reserved
55 = d-correction F+torque (SK 540E and
above)
13 = Multiplication
56 = reserved from SK 540E and above
BU
0510
14 = Process controller actual value
57 = reserved from SK 540E and above
BU
0510
15 = Process controller setpoint
Further functions are listed in the corresponding supplementary instructions (BU0510 for
POSICON, BU550 for PLC).
Pos: 110 /Anleitungen/5. Parametrierung/Parameter/P500-P599/Parameter P547
– Funktion Bus-Sollwert 2 [bis SK 535E] @ 0\mod_1328098180008_388.docx @ 11962 @ @ 1
P547
Func. bus-set point 2
(Function of bus - setpoint 2)
up to SK 535E
S
P
0 ... 55
{ 0 }
This parameter is identical to P546.
Pos: 111 /Anleitungen/5. Parametrierung/Parameter/P500-P599/Parameter P548
– Funktion Bus-Sollwert 3 [bis SK 535E] @ 0\mod_1328098278323_388.docx @ 11985 @ @ 1
P548
Func. bus-set point 3
(Function of bus - setpoint 3)
up to SK 535E
S
P
0 ... 55
{ 0 }
This parameter is identical to P546.
Pos: 112 /Anleitungen/5. Parametrierung/5.8 Informationen @ 0\mod_1328170311705_388.docx @ 12293 @ 3 @ 1