6 parameterisation, P543 bus actual value 1, P544 bus actual value 2 – NORD Drivesystems BU0020 User Manual
Page 57: P545 bus actual value 3
6 Parameterisation
BU 0020 GB-2612
57
P543
Bus actual value 1
(Actual bus value 1)
SK 300E /
SK 7x0E
S
P
0 ... 12
{ 1 }
The return value 1 can be selected for bus actuation in this parameter.
0 =
Off
6 =
Actual position (only with POSICON,
SK 7x0E)
1 =
Actual frequency
7 =
Setpoint position (only with
POSICON, SK 7x0E)
2 =
Actual speed
8 =
Setpoint frequency
3 =
Current
9 =
Error number
4 =
Torque current (100% = P112)
10 = Actual position increment (only with
POSICON, SK 7x0E)
4
5 =
Digital IO status
5
11 = Setpoint position increment (only with
POSICON, SK 7x0E)
12 = BusIO Out Bits 0...7
Pos: 80 /Anleitungen/5. Parametrierung/Parameter/P500-P599/Parameter P544
– Bus-Istwert 2 [SK 300E, SK 7x0E - PBR] @ 1\mod_1335786320688_388.docx @ 24904 @ @ 1
P544
Bus actual value 2
(Actual bus value 2)
SK 300E /
SK 7x0E
S
P
0 ... 12
{ 0 }
This parameter is identical to P543.
The condition is PPO 2 or PPO 4 type (P507 or rotary encoding switch on technology unit option
SK TUx-PBR-24V).
Pos: 81 /Anleitungen/5. Parametrierung/Parameter/P500-P599/Parameter P545
– Bus-Istwert 3 [SK 300E, SK 7x0E - PBR] @ 1\mod_1335786551087_388.docx @ 24928 @ @ 1
P545
Bus actual value 3
(Actual bus value 3)
SK 300E /
SK 7x0E
S
P
0 ... 12
{ 0 }
This parameter is identical to P543.
The condition is PPO 2 or PPO 4 type (P507 or rotary encoding switch on technology unit option
SK TUx-PBR-24V).
Pos: 82 /Anleitungen/5. Parametrierung/Parameter/P500-P599/Parameter P546
– Bus-Sollwert 1 [SK 300E, SK 7x0E] @ 1\mod_1335786897102_388.docx @ 24952 @ @ 1
4
Setpoint/actual position corresponding to an 8192 increment encoder.
5
The assignment of the digital inputs in P543/ 544/ 545 = 5 for SK 700E/ SK 750E
Bit 0 = DigIn 1
Bit 1 = DigIn 2
Bit 2 = DigIn 3
Bit 3 = DigIn 4
Bit 4 = DigIn 5
Bit 5 = DigIn 6
Bit 6 = DigIn 7 (POS or ENC)
Bit 7 = DigIn 8 (POS)
Bit 8 = DigIn 9 (POS)
Bit 9 = DigIn 10 (POS)
Bit 10 = DigIn 11 (POS)
Bit 11 = DigIn 12 (POS)
Bit 12 = REL 1
Bit 13 = REL 2
Bit 14 = REL 3 (POS)
Bit 15 = REL 4 (POS)