NORD Drivesystems BU2200 User Manual
Page 35
POWERLINK Bus module
–
Supplementary manual options for NORD - Frequency Inverters
BU 2200 GB-3813
35
List of bus errors to inverter errors
Error messages which are generated by the frequency inverter are transferred from the bus module to
the field bus level. They do not result in an error of the bus module.
The allocation of special error codes for NORD inverters is carried out as follows:
Error code
Error register
FI Error Code (error number P700) *
0x0000
0
0x1000
1
---
The error number transmitted by FI is not known to the
technology unit. It must be read out via (P700) or an actual
value.
0x2200
3
4.0 / 4.1
0x2310
3
3.0
0x2311
3
3.2
0x2312
3
3.3
0x3110
5
5.1
0x3120
5
6.1
0x3130
5
7.0
0x3210
5
5.0
0x3230
5
6.0
0x4210
9
1.1
0x4310
9
2.0 / 2.1 / 2.2
0x5000
1
10.8
0x5110
1
11.0
0x5300
1
17.0
0x5510
1
20.0
0x5520
1
20.8
0x5530
1
8.2
0x6000
1
15.0 … 15.8 / 20.1 up to 20.7 / 21.3
0x6310
1
8.0
0x7112
3
3.1
0x7120
1
16.0 / 16.1
0x7300
1
14.3
0x7305
1
13.0
0x7306
1
14.4
0x7310
1
14.5
0x7320
1
14.6 / 14.7 / 14.8
0x7330
1
25.0
0x7331
1
25.1
0x7332
1
25.2
0x7333
1
25.3
0x7334
1
25.4
0x8100
17
10.0 / 10.1 / 10.2
0x8111
17
10.3 up to 10.7 / 10.9
0x8300
1
13.2
0x8400
1
13.1
0x8600
1
14.0 / 14.1
0x8612
1
14.2
0x8710
1
13.5
0x8711
1
13.6