POWERLINK Bus module
–
Supplementary manual options for NORD - Frequency Inverters
BU 2200 GB-3813
31
Param
eter
Parameter name
Recommended setting
Remarks
SK 5xxE
SK
180E … SK
2xxE
status
starting disabled condition
P701
Last fault
P740
Process data BUS In
P741
Process data BUS Out
P742
Data base version
P744
Configuration
Not relevant
P745
Module version
Not available
P746
Module status
Not available
Possible values
Bit
Meaning
0
Module initialised
1
Cyclical communication
2
Vacant
3
Vacant
4
Error 1
5
Error 2
6
Error 3
7
Vacant
8-15
Module number
POWERLINK = 24
Table of Errors
error
Meaning
3
2
1
0
0
0
No error
0
0
1
No communication
with ASIC
0
1
0
Bus Timeout
0
1
1
P513 timeout
P748
CANopen status
Not relevant for
SK TU3 modules
System bus status
Table 17: Overview of Frequency Inverter Parameters