5 Parameter
26
BU 2200 GB-3813
P162
Device name
(Device name)
SK TU3-POL
SK xU4-POL
8 bit
ASCii
{ 0 }
Name of the bus module in the POWERLINK network
If no device name is given, the module logs into the Powerlink network with the default name
"Powerlink
The settings are only adopted after a restart of the module.
Pos : 53 /Anl eitungen/ Elektroni k/ Par ameter/ P100-P199/ Buss pezi fisch/PO WER LIN K/ Par amet er P163
– FU setzt Busfehl er [SK xU x-POL] @ 4\mod_1378887891220_388.doc x @ 94490 @ @ 1
P163
FU sets bus error
(FI sets bus error)
SK TU3-POL
SK xU4-POL
8 bit
0 … 1
{ 1 }
If this function is enabled (1), the bus module sends an error message in case of a fault. With the
setting (0), a status message is sent.
Pos : 54 /Anl eitungen/ Elektroni k/ Par ameter/ P100-P199/ Buss pezi fisch/PO WER LIN K/ Par amet er P164
– IP Gateway [SK xU x- POL] @ 4\mod_1378888096666_388.doc x @ 94514 @ @ 1
P164
... [-01]
…
... [-04]
IP Gateway
(IP Gateway)
SK TU3-POL
SK xU4-POL
8 bit
0 ... 255
{ [-01] = 192 }
{ [-02] = 168 }
{ [-03] = 100 }
{ [-04] = 254 }
Parameterised IP address of the gateway consisting of four bytes.
The Ethernet POWERLINK Standardization Group (EPSG) recommends that the IP address
remains at the the default address.
The setting is only adopted after a restart of the module.
[-01] = IP High (Net-ID)
[-02] = IP (Net-ID)
[-03] = IP (Net-ID)
[-04] = IP Lo (Host)
Pos : 55 /Anl eitungen/ Elektroni k/ Par ameter/ P100-P199/ Buss pezi fisch/PO WER LIN K/ Par amet er P165
– POWER LIN K Z yklus [SK xU x-POL] @ 4\mod_1378888765733_388.doc x @ 94538 @ @ 1
P165
POWERLINK Cycle
(POWERLINK cycle time)
SK TU3-POL
SK xU4-POL
16 bit
400 … 20000 µs
{ 1000 }
The bus cycle time which is set is used for synchronisation with the Manage Node.
Pos : 56 /Anl eitungen/ Elektroni k/ Bus s yst eme/5. Par ameter/ P17x I nf ormati ons Paramet er
– Bus , allgemei n @ 3\mod_1369132034911_388.doc x @ 69995 @ 5 @ 1
General Bus InformationParameters (P17x)
Parameter
Setting value / Description / Note
Device
Type
Pos : 57 /Anl eitungen/ Elektroni k/ Par ameter/ P100-P199/ Buss pezi fisch/Bus übergreif end [ P150 ff. - P180 ff. ]/Par amet er P170
– Aktuell er Fehler [SK xU x- ..., SK EBIOE] @ 3\mod_1368776868873_388.doc x @ 69554 @ @ 1
P170
... [-01]
... [-02]
Present Error
(Present Error)
SK
EB…
SK TU3-
…
SK xU4-
…
8 bit
0 ... 9999
Error present in the bus module. The error message is reset when the supply voltage is switched
off.
[-01] = Present module error
[-02] = Last error message from module
For a list of possible error messages, please refer to the section "Error Monitoring and
Error Messages".
Pos : 58 /Anl eitungen/ Elektroni k/ Par ameter/ P100-P199/ Buss pezi fisch/Bus übergreif end [ P150 ff. - P180 ff. ]/Par amet er P171
– Softwar e-Version [SK xU x-..., SK EBIOE] @ 3\mod_1368785436095_388.doc x @ 69604 @ @ 1