Table 16: error codes for parameter access failure – NORD Drivesystems BU2200 User Manual
Page 23
POWERLINK Bus module
–
Supplementary manual options for NORD - Frequency Inverters
BU 2200 GB-3813
23
Interruption of parameter communication (SDO)
If problems occur during parameter communication (e.g. value range overflow), a cancel telegram is
sent. The error codes comply with the POWERLINK standard EPSG DS 301.
Pos : 41 /Anl eitungen/ Elektroni k/ Bus s yst eme/4. Kommuni kati on und Prot okoll + Proz ess datentr ans fer /POWER LIN K [ BU 02200]/F ehl ercodes f ür den g esc heit ert en Paramet erzugriff [SK xU x-PO L] @ 4\ mod_1378807315893_388. doc x @ 93921 @ @ 1
Error code
Explanation
0x0504 0000
Timeout of the SDO response by the bus module
0x0504 0001
Unknown SDO command
0x0504 0002
The size of the transferred data is not correct
0x0504 0003
Error in sequence layer
0x0504 0005
Insufficient memory
0x0601 0000
Access to the object is not supported
0x0601 0001
Reading access to write-only parameter
0x0601 0002
Writing access to a read-only parameter
0x0602 0000
Access to a non-existent parameter
0x0604 0043
Incompatible parameter
0x0604 0047
Internal incompatibility in module
0x0606 0000
Hardware error
0x0607 0010
The data type does not match the length of access
0x0607 0012
Parameter access with excess data length
0x0607 0013
Parameter access with insufficient data length
0x0609 0011
Parameter sub-index does not exist
0x0609 0030
Parameter value range overflow
0x0609 0031
Parameter value too large
0x0609 0032
Parameter value too small
0x0609 0036
Maximum value smaller than the minimum value
0x0800 0000
General error
0x0800 0020
Reading / writing of parameter not possible as there is no connection between the FI and the
module
0x0800 0021
Module does not react
Table 16: Error codes for parameter access failure