5 Parameter

28

BU 2200 GB-3813

Bit 0 =

Digital input 1

Bit 1 =

Digital input 2

Bit 2 =

Digital input 3*

Bit 3 =

Digital input 4*

Bit 4 =

Digital input 5**

Bit 5 =

Digital input 6**

Bit 6 =

Digital input 7**

Bit 7 =

Digital input 8**

* Except for ... CU4- modules

** Only SK TU4-ECT, SK TU4-EIP, SK TU4-PNT and SK TU4-POL

Pos : 62 /Anl eitungen/ Elektroni k/ Par ameter/ P100-P199/ Buss pezi fisch/Bus übergreif end [ P150 ff. - P180 ff. ]/Par amet er P175

– Baugruppenz us tand [SK TU4-..., SK EBIOE] @ 3\mod_1369119434666_388.doc x @ 69704 @ @ 1

P175

Relay Status

(Switching status of relay)

SK

EB…

SK TU4-

8 bit

0 ... 3

Image of the switching status of the relay outputs of the module.

Bit 0 =

Relay 1

Bit 1 =

Relay 2

Pos : 63 /Anl eitungen/ Elektroni k/ Par ameter/ P100-P199/ Buss pezi fisch/Bus übergreif end [ P150 ff. - P180 ff. ]/Par amet er P176

– Pr oz eßdaten Bus In [SK xU x-...] @ 3\mod_1369120373047_388.doc x @ 69728 @ @ 1

P176

... [-01]

... [-25]

Process Data Bus In

(Process data Bus In)

SK TU3-

SK xU4-

16 bit

-32768 ... 32767

Bus data received from Bus Master / controller

[-01] = Bus module outputs*

[-02] = Control word FI 1

[-03] = Setpoint 1 for FI 1

[-04] = Setpoint 2 for FI 1

[-05] = Setpoint 3 for FI 1

[-06] = Setpoint 4 for FI 1

[-07] = Setpoint 5 for FI 1

[-08] = Control word FI 2*

[-09] = Setpoint 1 for FI 2*

[-10] = Setpoint 2 for FI 2*

[-11] = Setpoint 3 for FI 2*

[-12] = Setpoint 4 for FI 2*

[-13] = Setpoint 5 for FI 2*

[-14] = Control word FI 3*

[-15] = Setpoint 1 for FI 3*

[-16] = Setpoint 2 for FI 3*

[-17] = Setpoint 3 for FI 3*

[-18] = Setpoint 4 for FI 3*

[-19] = Setpoint 5 for FI 3*

[-20] = Control word FI 4*

[-21] = Setpoint 1 for FI 4*

[-22] = Setpoint 2 for FI 4*

[-23] = Setpoint 3 for FI 4*

[-24] = Setpoint 4 for FI 4*

[-25] = Setpoint 5 for FI 4*

* Except for SK TU3 versions

Pos : 64 /Anl eitungen/ Elektroni k/ Par ameter/ P100-P199/ Buss pezi fisch/PO WER LIN K/ Par amet er P176

– Pr oz eßdaten Bus In (Ergänz ung POWERLINK) [SK xU x- POL] @ 4\mod_1378889464526_388.doc x @ 94562 @ @ 1

Information

Control data via UDP

Control data via UDP are only displayed if there is no POWERLINK master.

Pos : 65 /Anl eitungen/ Elektroni k/ Par ameter/ P100-P199/ Buss pezi fisch/Bus übergreif end [ P150 ff. - P180 ff. ]/Par amet er P177

– Pr oz eßdaten Bus Out [SK xU x- ...] @ 3\mod_1369125104371_388.doc x @ 69776 @ @ 1