Frequency inverter parameters, 5 parameter, Nmt statechangecount – NORD Drivesystems BU2200 User Manual
Page 30: Present ip address, Present ip sub-net mask, 2 frequency inverter parameters
![background image](/manuals/372769/30/background.png)
5 Parameter
30
BU 2200 GB-3813
P184
... [-01]
…
... [-06]
NMT Statechangecount
(NMT Status change)
SK TU3-POL
SK xU4-POL
8 bit
0 ... 2
31
Counter for the error which caused the last change of state The counter readings are deleted
after a restart!
[-01] = Loss of SoC (cyclic data lost)
[-02] = Jitter of SoC (Timeout of cyclic data)
[-03] = Loss of PReq (MN not responding)
[-04] = Loss of SoA (acyclic frame lost)
[-05] = Collision (data collision)
[-04] = CRC Error (transfer error)
Pos : 71 /Anl eitungen/ Elektroni k/ Par ameter/ P100-P199/ Buss pezi fisch/Bus übergreif end [ P150 ff. - P180 ff. ]/Par amet er P185
– Akt. IP Adresse [SK xU x-...] @ 3\mod_1369128043016_388.doc x @ 69872 @ @ 1
P185
... [-01]
…
... [-04]
Present IP Address
(Present IP Address)
SK TU3-
…
SK xU4-
…
8 bit
0 ... 255
Displays the present IP address
[-
01] … [-04] = IP Address
xxx . xxx . xxx . xxx
Pos : 72 /Anl eitungen/ Elektroni k/ Par ameter/ P100-P199/ Buss pezi fisch/Bus übergreif end [ P150 ff. - P180 ff. ]/Par amet er P186
– Akt. IP Subnetz mas ke [SK xU x-...] @ 3\mod_1369129573087_388.doc x @ 69896 @ @ 1
P186
... [-01]
…
... [-04]
Present IP Sub-net Mask
(Present IP Sub-net mask)
SK TU3-
…
SK xU4-
…
8 bit
0 ... 255
Displays the present IP sub-net mask.
[-
01] … [-04] = IP Sub-net mask
xxx . xxx . xxx . xxx
Pos : 73 /Anl eitungen/ Elektroni k/ Bus s yst eme/5. Par ameter/ PO WERLINK [ BU 2200]/ Par ameter Fr equenz umrichter [SK xU x- PO L] @ 4\ mod_1379408292183_388. doc x @ 98762 @ 2 @ 1
5.2 Frequency Inverter Parameters
Various parameters of the frequency inverter are relevant for the commissioning of the bus system or
the frequency inverter in the bus system and may need to be changed.
A detailed description of the inverter parameters can be found in the manual for the relevant frequency
inverter.
Param
eter
Parameter name
Recommended setting
Remarks
SK 5xxE
SK
180E … SK
2xxE
P120
Option monitoring
Not available, or not
relevant for SK TU3
modules
{1} = Auto
P509
Control word source
{8} = Ethernet TU
{3} = System bus
P510
Setpoint source
{0} = Auto
{0} = Auto
P513
Telegram timeout
{0.5} = 0.5s
{0.0} = Off
Do not set this value too low
P543
Actual BUS value
Acc. to the function:
According to the
function:
SK 54xE and SK
180E …
SK 2xxE: up to 5 actual
values each
P544
Actual BUS value 2
Acc. to the function:
Not available
Only SK
500E … 535E
P545
Actual BUS value 3
Acc. to the function:
Not available
Only SK
500E … 535E
P546
Funct. Setpoint BUS
value
Acc. to the function:
According to the
function:
SK 54xE and SK
180E …
SK 2xxE: up to 5 setpoints
each
P547
Funct. BUS setpoint 2
Acc. to the function:
Not available
Only SK
500E … 535E
P548
Funct. BUS setpoint 3
Acc. to the function:
Not available
Only SK
500E … 535E
Info parameters
P700
Present
Operating
Fault / Warnings / Reason for