Chillers deltachill, Chillers – Airedale DeltaChill FreeCool 110kW - 1080kW User Manual
Page 129

Chillers
DELTACHILL
™
Chillers
129
Technical Manual :7022932_V1.9_11/2013
Electrical Data Free Cool Chiller Extra Quiet Continued
ELECTRICAL DATA
DCF023DX-06BKK0
DCF026DX-08BKL0
DCF029DX-08BLL0
Unit Data
Nominal Run Amps
(1)
A
147.1
172.2
192.2
Maximum Start Amps
A
329.1
389.1
409.2
Recommended Mains Fuse Size
A
160
200
250
Mains Supply
VAC
400 V 3 PH 50 Hz
Max Mains Incoming Cable Size
mm²
Direct to Bus Bar
Recommended Permanent Fuse Size
A
16
16
16
Permanent Supply
VAC
230 V 1 PH 50 Hz
Max Permanent Incoming Cable Size
mm²
4 mm² terminals
Control Circuit
VAC
24V/230VAC
Evaporator
Pad Heater Rating
W
100
100
100
External Trace Heating
Available (fitted by others)
W
500
500
500
Condenser Fan - Per Fan (AC)
Quantity
6
8
8
Full Load Amps
A
2.5
2.5
2.5
Locked Rotor Amps
A
8.8
8.8
8.8
Motor Rating
kW
1.27
1.27
1.27
Condenser Fan - Per Fan (EC)
Quantity
6
8
8
Full Load Amps
A
3.9
3.9
3.9
Locked Rotor Amps
A
N/A
N/A
N/A
Motor Rating
kW
2.56
2.56
2.56
Compressor - Per Compressor
Nominal Run Amps
A
33.0 / 33.0
33.0 / 43.1
43.1 / 43.1
Quantity
2 + 2
2 + 2
2 + 2
Motor Rating
kW
18.8 / 18.8
18.8 / 24.0
24.0 / 24.0
Sump Heater Rating
W
75
75
75
Start Amps
A
215 / 215
215 / 260
260 / 260
Type Of Start
Direct on line
OPTIONAL EXTRAS
Power Factor Correction
Circuit 1 Comp RLA (PFC)
28.5
28.5
36.5
Circuit 2 Comp RLA (PFC)
28.5
36.5
36.5
Nominal Run Amps
A
129.0
150.0
165.9
Maximum Start Amps
A
315.5
373.5
389.5
Compressor Nominal Run Amps
A
28.5 / 28.5
28.5 / 36.5
36.5 / 36.5
Recommended Mains Fuse Size
A
160
200
250
Electronic Soft-start
Nominal Run Amps
A
147.1
172.2
192.2
Maximum Start Amps
A
243.1
285.1
305.2
Recommended Mains Fuse
A
160.0
200.0
250.0
Power Factor Correction & Electronic Soft Start
Nominal Run Amps
A
129.0
150.0
165.9
Maximum Start Amps
A
229.5
269.5
285.5
Compressor Nominal Run Amps
A
28.5 / 28.5
28.5 / 36.5
36.5 / 36.5
Recommended Mains Fuse Size
A
160
200
250
Condenser Fan - Per Fan (EC Extra Freecooling)
Quantity
N/A
N/A
N/A
Full Load Amps
A
N/A
N/A
N/A
Locked Rotor Amps
A
N/A
N/A
N/A
Motor Rating
kW
N/A
N/A
N/A
Standard Head Pump (Single or Run/Standby)
Pump Full Load Amps
A
8.9
12
12
Unit Nominal Run Amps
A
156.0
184.2
204.2
Recommended Mains Fuse Size
A
200
250
250
Motor Rating
kW
4
5.5
5.5
Larger Head Pump (Single or Run/Standby)
Pump Full Load Amps
A
11.8
11.8
14
Unit Nominal Run Amps
A
158.9
184.0
206.2
Recommended Mains Fuse Size
A
200
200
250
Motor Rating
kW
5.5
5.5
7.5
Standard Head Inverter Pump (Single or Run/Standby)
Pump Full Load Amps
A
8
11.2
11.2
Unit Nominal Run Amps
A
155.1
183.4
203.4
Recommended Mains Fuse Size
A
200
250
250
Motor Rating
kW
4
5.5
5.5
Larger Head Inverter Pump (Single or Run/Standby)
Pump Full Load Amps
A
11.2
14.8
14.8
Unit Nominal Run Amps
A
158.3
187.0
207.0
Recommended Mains Fuse Size
A
200
200
250
Motor Rating
kW
5.5
7.5
7.5
(1) Based at 7.2°C Evap / 54.4°C Condensing, AC Standard Fans.
(2) Starting amps refers to the direct on line connections.