Electrical data free cool chiller extra quiet, Deltachill ™ chillers, Chillers – Airedale DeltaChill FreeCool 110kW - 1080kW User Manual
Page 126

DELTACHILL
™
Chillers
126
Chillers
Technical Manual : 7022932_V1.9_11/2013
Electrical Data Free Cool Chiller Extra Quiet
ELECTRICAL DATA
DCF017SX-04AM00
DCF021SX-06BS00
DCF025SX-06BT00
Unit Data
Nominal Run Amps
(1)
A
105.0
144.2
157.5
Maximum Start Amps
A
377.5
318.1
382.5
Recommended Mains Fuse Size
A
125
200
200
Mains Supply
VAC
400 V 3 PH 50 Hz
Max Mains Incoming Cable Size
mm²
Direct to Bus Bar
Recommended Permanent Fuse Size
A
16
16
16
Permanent Supply
VAC
230 V 1 PH 50 Hz
Max Permanent Incoming Cable Size
mm²
4 mm² terminals
Control Circuit
VAC
24V/230VAC
Evaporator
Pad Heater Rating
W
80
100
100
External Trace Heating
Available (fitted by others)
W
500
500
500
Condenser Fan - Per Fan (AC)
Quantity
4
6
6
Full Load Amps
A
2.5
2.5
2.5
Locked Rotor Amps
A
8.8
8.8
8.8
Motor Rating
kW
1.27
1.27
1.27
Condenser Fan - Per Fan (EC)
Quantity
4
6
6
Full Load Amps
A
3.9
3.9
3.9
Locked Rotor Amps
A
N/A
N/A
N/A
Motor Rating
kW
2.56
2.56
2.56
Compressor - Per Compressor
Nominal Run Amps
A
47.5
43.1
47.5
Quantity
2
3
3
Motor Rating
kW
28.2
24.0
28.2
Sump Heater Rating
W
130
75
130
Start Amps
A
320
260
320
Type Of Start
Direct on line
OPTIONAL EXTRAS
Power Factor Correction
Circuit 1 Comp RLA (PFC)
42.8
36.5
42.8
Circuit 2 Comp RLA (PFC)
N/A
N/A
N/A
Nominal Run Amps
A
95.6
124.5
143.4
Maximum Start Amps
A
372.8
311.5
377.8
Compressor Nominal Run Amps
A
42.8
36.5
42.8
Recommended Mains Fuse Size
A
125
160
200
Electronic Soft-start
Nominal Run Amps
A
105.0
144.2
157.5
Maximum Start Amps
A
249.5
257.1
302.0
Recommended Mains Fuse
A
125.0
200.0
200.0
Power Factor Correction & Electronic Soft Start
Nominal Run Amps
A
95.6
124.5
143.4
Maximum Start Amps
A
244.8
244.0
292.6
Compressor Nominal Run Amps
A
42.8
36.5
42.8
Recommended Mains Fuse Size
A
125
160
200
Condenser Fan - Per Fan (EC Extra Freecooling)
Quantity
N/A
N/A
N/A
Full Load Amps
A
N/A
N/A
N/A
Locked Rotor Amps
A
N/A
N/A
N/A
Motor Rating
kW
N/A
N/A
N/A
Standard Head Pump (Single or Run/Standby)
Pump Full Load Amps
A
8.9
8.9
8.9
Unit Nominal Run Amps
A
113.9
153.1
166.4
Recommended Mains Fuse Size
A
160
200
200
Motor Rating
kW
4
4
4
Larger Head Pump (Single or Run/Standby)
Pump Full Load Amps
A
11.8
11.8
11.8
Unit Nominal Run Amps
A
116.8
156.0
169.3
Recommended Mains Fuse Size
A
160
200
200
Motor Rating
kW
5.5
5.5
5.5
Standard Head Inverter Pump (Single or Run/Standby)
Pump Full Load Amps
A
6.3
8
11.2
Unit Nominal Run Amps
A
111.3
152.2
168.7
Recommended Mains Fuse Size
A
160
200
200
Motor Rating
kW
3
4
5.5
Larger Head Inverter Pump (Single or Run/Standby)
Pump Full Load Amps
A
8
11.2
14.8
Unit Nominal Run Amps
A
113.0
155.4
172.3
Recommended Mains Fuse Size
A
160
200
200
Motor Rating
kW
4
5.5
7.5
(1) Based at 7.2°C Evap / 54.4°C Condensing, AC Standard Fans.
(2) Starting amps refers to the direct on line connections.