beautypg.com

SHIMPO DT-365E User Manual

Page 18

background image

18

4.4.3.1 How to set the delay

The delay angle from the pulse input to emission can be set by 0.1º within the range between 1º

and 359º by setting one cycle of the external trigger pulse to 360º. Measure the external trigger

pulse frequency per cycle, and calculate the delay angle based on the measured frequency to

perform the delay emission. Since a delay of approximately 20 μs always occurs for the internal

calculation, the actual delay time is calculated as follows:

Delay setting angle

x External trigger pulse cycle + Approximately 20 μs

360°

[Example 1] When setting the input frequency to 10 Hz (600 fpm), trigger edge to "rising",

and delay angle to 36º

External trigger pulse
(Pulse entered from an

external device to DT-365E)

Strobe emission

100ms(360°)

10ms(36°)

Frequency

calculation

Delay

Emission

Frequency

calculation

100ms(360°)

10ms(36°)

Delay

Emission

• Since the delay angle is calculated based on the previously entered external trigger pulse cycle, if

the external trigger pulse frequency changes, emission cannot be performed at a precise angle.

Also, since the external trigger pulse cycle becomes shorter than the previous pulse cycle, if the

next external trigger pulse is entered before delay angle emission, the delay angle setting will be

disabled, and emission is performed simultaneously(*) with the external trigger pulse.

• When the delay angle is set to 0º, emission is performed simultaneously(*) with the external

trigger pulse.

(*Since there is a delay caused by the internal calculation process, the strobe actually emits light in

approximately 20 μs after the external trigger pulse is entered.)

Turn the dial to the right to increase the delay angle setting value. Increasing the setting value from

359º will be 0º.

4.4.4 Saving the setting values

While using the unit while on internal oscillation emission and external synchronous emission,

press the power switch and turn the power OFF to save the setting value to that which it was before

turning the power OFF.

When the power is turned ON again, operation starts from the previous setting value.

When the power is OFF, the following setting values are saved.

During internal oscillation emission

During external synchronous

emission

Emission setting

Mode setting

Frequency setting

-

Emission duration

Delay angle