STATUS

Status

R

Digital transducers, unlike their analog versions, can detect

faults that make the measurement bad or prevent the

actuator from responding. This additional, valuable

information will be passed along with each transmission of a

data value in the form of a status attribute.

-

VALUE

Value

R

A numerical quantity entered by a user or calculated by the

algorithm.

-

PRIMARY_VALUE_

PRIMARY_VALUE_

PRIMARY_VALUE_

PRIMARY_VALUE_

RANGE_3

RANGE_3

RANGE_3

RANGE_3

Primary Value

Primary Value

Primary Value

Primary Value

Range - Sensor 3

Range - Sensor 3

Range - Sensor 3

Range - Sensor 3

The High and Low range limit values, the engineering units

code and the number of digits to the right of the decimal point

to be used to display the Primary Value.

EU_100

max value

R

The engineering unit value which represents the upper end of

range of the associated block parameter.

100

EU_0

min value

R

The engineering unit value which represents the lower end of

range of the associated block parameter.

0.0

UNITS_INDEX

Units Index

RW

Device Description units code index for the engineering unit

descriptor for the associated block value.

Setting:

kgal; L; ImpGal; m³; bbl; ft³; m; cm; mm; in; ft; kg, t; STon;

LTon

DECIMAL

Decimal

R

The number of digits to the right of the decimal point which

should be used by an interface device in displaying the

specified parameter.

0

PRIMARY_VALUE_TYPE_4

PRIMARY_VALUE_TYPE_4

PRIMARY_VALUE_TYPE_4

PRIMARY_VALUE_TYPE_4

Primary Value Type

Primary Value Type

Primary Value Type

Primary Value Type

R

The type of measurement represented by the primary value.

For Example: Mass Flow, Absolute Pressure, Differential

Temperature.

Conversion

Distance

PRIMARY_VALUE_4

PRIMARY_VALUE_4

PRIMARY_VALUE_4

PRIMARY_VALUE_4

Conversion Distance

Conversion Distance

Conversion Distance

Conversion Distance

The measured conversion distance value and status of

available to the Function Block.

STATUS

Status

R

Digital transducers, unlike their analog versions, can detect

faults that make the measurement bad or prevent the

actuator from responding. This additional, valuable

information will be passed along with each transmission of a

data value in the form of a status attribute.

-

VALUE

Value

R

A numerical quantity entered by a user or calculated by the

algorithm.

-

PRIMARY_VALUE_

PRIMARY_VALUE_

PRIMARY_VALUE_

PRIMARY_VALUE_

RANGE_4

RANGE_4

RANGE_4

RANGE_4

level range

level range

level range

level range

The High and Low range limit values, the engineering units

code and the number of digits to the right of the decimal point

to be used to display the Primary Value.

EU_100

max value

R

The engineering unit value which represents the upper end of

range of the associated block parameter.

15.0

EU_0

min value

R

The engineering unit value which represents the lower end of

range of the associated block parameter.

0.0

UNITS_INDEX

Units Index

RW

Device Description units code index for the engineering unit

descriptor for the associated block value.

m

Settings:

m; cm; mm; ft; in; yd

DECIMAL

Decimal

R

The number of digits to the right of the decimal point which

should be used by an interface device in displaying the

specified parameter.

0

PROBE_END_PULSE_TYPE

PROBE_END_PULSE_TYPE

PROBE_END_PULSE_TYPE

PROBE_END_PULSE_TYPE

Probe end pulse type

Probe end pulse type

Probe end pulse type

Probe end pulse type

RW

Probe end pulse type

Setting:

Probe end disabled / emitted sign / opposite emitted sign

Parameter

Parameter

Parameter

Parameter
DD name

Access Description and settings

Initial Value