4

OPERATION

28

OPTIFLEX 2200 C

www.krohne.com

09/2013 - 4002573201 - AD FF OPTIFLEX 2200 R01 en

FD_OFFSPEC_ACTIVE

FD_OFFSPEC_ACTIVE

FD_OFFSPEC_ACTIVE

FD_OFFSPEC_ACTIVE

Offspec Active

Offspec Active

Offspec Active

Offspec Active

R

This parameter reflects the error conditions that are being detected

as active as selected for this category. It is a bit string, so that

multiple conditions may be shown.

Setting:

(00) Check Function

(01) Cond01

(02) Cond02

(03) Cond03

(04) Cond04

(05) Cond05

(06) Snapshot invalid

(07) Audio Signal Offset outside Range

(08) Reference Position outside Range

(09) Pulse Flange Lost

(10) No Probe detected

(11) Reference Lost Error

(12) Oscillator Frequency failure

(13) Temperature Above +75°C

(14) Temperature Below -35°C

(15) Overfill Warning

(16) Level Lost warning

(17) Temperature out of range (warning)

(18) Local operation

(19) Overfill Error

(20) Level lost error

(21) Temperature out of range Error

(22) Converter Voltage Error

(23) Converter ROM Error

(24) Converter RAM Error

(25) Converter EEPROM Error

(26) Sensor not compatible

(27) Internal Communication Error

(28) Sensor Voltage Error

(29) Sensor ROM Error

(30) Sensor RAM Error

(31) Sensor EEPROM Error

FD_OFFSPEC_ALM

FD_OFFSPEC_ALM

FD_OFFSPEC_ALM

FD_OFFSPEC_ALM

Offspec Alarm

Offspec Alarm

Offspec Alarm

Offspec Alarm

This parameter is used primarily to broadcast a change in the

associated active conditions, which are not masked, for this alarm

category to a Host System.

UNACKNOWLEDGED

Unacknowledged

RW

A discrete enumeration which is set to Unacknowledged when an

alarm occurs, and set to Acknowledged by a write from a human

interface device or other entity which can acknowledge that the

alarm/event has been noticed.

Uninitialized

Setting:

Uninitialized / Acknowledged / Unacknowledged

ALARM_STATE

Alarm State

R

A discrete enumeration which gives an indication of whether the

alert is active and whether it has been reported.

Uninitialized

Setting:

Uninitialized / Clear - reported / Clear - not reported / Active -

reported / Active - not reported

TIME_STAMP

Time Stamp

R

The time when evaluation of the block was started and a change in

alarm/event state was detected that is unreported. The time stamp

value will be maintained constant until alert confirmation has been

received – even if another change of state occurs.

Uninitialized

Setting:

MM / DD / YY (Month / Day / Year)

HH:MM:SS (Hour:Minute:Second)

Parameter

Parameter

Parameter

Parameter
DD name

Access Description and settings

Initial Value