beautypg.com

Operation – KROHNE PTIFLEX 2200 FOUNDATION FIELDBUS User Manual

Page 17

background image

OPERATION

4

17

OPTIFLEX 2200 C

www.krohne.com

09/2013 - 4002573201 - AD FF OPTIFLEX 2200 R01 en

ITK_VER

ITK_VER

ITK_VER

ITK_VER

ITK Version

ITK Version

ITK Version

ITK Version

(Interoperatibility Test

Kit)

R

Major revision number of the interoperability test case used to

register this device.

6.1

LIM_NOTIFY

LIM_NOTIFY

LIM_NOTIFY

LIM_NOTIFY

Limit Notify

Limit Notify

Limit Notify

Limit Notify

R/W

Maximum number of unconfirmed alert notify messages

allowed.

20

Setting:

0...255

MANUFAC_ID

MANUFAC_ID

MANUFAC_ID

MANUFAC_ID

Manufacturer ID

Manufacturer ID

Manufacturer ID

Manufacturer ID

R

Manufacturer identification number - used by an interface

device to locate the DD file for the resource.

KROHNE

Setting:

KROHNE

MAX_NOTIFY

MAX_NOTIFY

MAX_NOTIFY

MAX_NOTIFY

Maximum Notify

Maximum Notify

Maximum Notify

Maximum Notify

R

Maximum number of unconfirmed alert notify messages

possible.

20

Setting:

0...255

MEMORY_SIZE

MEMORY_SIZE

MEMORY_SIZE

MEMORY_SIZE

Memory Size

Memory Size

Memory Size

Memory Size

R

Available configuration memory in the empty resource. To be

checked before attempting a download.

0

MIN_CYCLE_T

MIN_CYCLE_T

MIN_CYCLE_T

MIN_CYCLE_T

Minimium Cycle Time

Minimium Cycle Time

Minimium Cycle Time

Minimium Cycle Time

R

Time duration of the shortest cycle interval of which the

resource is capable (in [1/32 ms]).

6400

NV_CYCLE_T

NV_CYCLE_T

NV_CYCLE_T

NV_CYCLE_T

Nonvolatile Cycle

Nonvolatile Cycle

Nonvolatile Cycle

Nonvolatile Cycle

Time

Time

Time

Time

R

Interval between writing copies of NV parameters to non-

volatile memory. Zero means never (in [1/32 ms]).

256000

RESTART

RESTART

RESTART

RESTART

Restart

Restart

Restart

Restart

RW

Allows a manual restart to be initiated. Several degrees of

restart are possible. They are 1: Run, 2: Restart resource,

3: Restart with defaults and 4: Restart processor.

Run

Setting:

Uninitialized / Run / Resource / Defaults / Processor

RS_STATE

RS_STATE

RS_STATE

RS_STATE

Resource State

Resource State

Resource State

Resource State

R

State of the function block application state machine.

Standby

Setting:

Uninitialized / StartRestart / Initialization / Online Linking /

Online / Standby / Failure

SET_FSTATE

SET_FSTATE

SET_FSTATE

SET_FSTATE

Set Fault State

Set Fault State

Set Fault State

Set Fault State

RW

Allows the fault state condition to be manually initiated by

selecting "SET".

OFF

Setting:

Unintialized / OFF / SET

SHED_RCAS

SHED_RCAS

SHED_RCAS

SHED_RCAS

Shed Remote Cascade

Shed Remote Cascade

Shed Remote Cascade

Shed Remote Cascade

R/W

Time duration at which to give up on computer writes to

function block RCAS locations.

640000

Setting:

0...4294967295 in [1/32 ms]

SHED_ROUT

SHED_ROUT

SHED_ROUT

SHED_ROUT

Shed Remote Out

Shed Remote Out

Shed Remote Out

Shed Remote Out

RW

Time duration at which to give up on computer writes to

function block ROUT locations.

640000

Setting:

0...4294967295 in [1/32 ms]

TEST_RW

TEST_RW

TEST_RW

TEST_RW

Test R Write

Test R Write

Test R Write

Test R Write

Read/write test parameter - used only for conformance

testing.

Note: Subelements "1..15" have no function!

-

UPDATE_EVT

UPDATE_EVT

UPDATE_EVT

UPDATE_EVT

Update Event

Update Event

Update Event

Update Event

This alert is generated by any change to the static data.

-

Parameter

Parameter

Parameter

Parameter
DD name

Access

Description and settings

Initial Value