Operation – KROHNE PTIFLEX 2200 FOUNDATION FIELDBUS User Manual

Page 44

background image

4

OPERATION

44

OPTIFLEX 2200 C

www.krohne.com

09/2013 - 4002573201 - AD FF OPTIFLEX 2200 R01 en

COUNTERWEIGHT_HEIGHT

COUNTERWEIGHT_HEIGHT

COUNTERWEIGHT_HEIGHT

COUNTERWEIGHT_HEIGHT

Counterweight height

Counterweight height

Counterweight height

Counterweight height

RW

For installations where a cable probe is used with a

counterweight attached to it this parameter specifies the

height of the counterweight.

Setting:

0...PROBE_LENGTH

EMPTY_AREA

EMPTY_AREA

EMPTY_AREA

EMPTY_AREA

Empty Area

Empty Area

Empty Area

Empty Area

RW

Empty Area

Setting:

0...PROBE_LENGTH

EPSILON_R_GAS

EPSILON_R_GAS

EPSILON_R_GAS

EPSILON_R_GAS

Dielectric constant of the

Dielectric constant of the

Dielectric constant of the

Dielectric constant of the

gas

gas

gas

gas

RW

A major parameter for TDR level measurement devices. If the

gas above the filling medium is not air, set this value to the

dielectric constant of the gas.

Setting:

0.8...115

EPSILON_R_PRODUCT

EPSILON_R_PRODUCT

EPSILON_R_PRODUCT

EPSILON_R_PRODUCT

Dielectric constant of the

Dielectric constant of the

Dielectric constant of the

Dielectric constant of the

product

product

product

product

RW

For measurement in TBF mode: Specifies the dielectric

constant of the product. If possible, type in the exact value. If

you do not know the exact value, use param.

AUTO_EPSILON_R for automatic calculation of the exact

value. A new dielectric constant that is too low will mean that

level will read higher than its true value.

Setting:

1...115

FULL_AREA

FULL_AREA

FULL_AREA

FULL_AREA

RW

Full Area

Setting:

0...PROBE_LENGTH

LEVEL_LOST

LEVEL_LOST

LEVEL_LOST

LEVEL_LOST

Level Lost Alarm

Level Lost Alarm

Level Lost Alarm

Level Lost Alarm

RW

Level Lost Alarm

Setting:

Warning / Error

LEVEL_OF_POINT_1_15

LEVEL_OF_POINT_1_15

LEVEL_OF_POINT_1_15

LEVEL_OF_POINT_1_15

Level table

Level table

Level table

Level table

RW

Table entries 1-15 containing level values.

LEVEL_OF_POINT_16_30

LEVEL_OF_POINT_16_30

LEVEL_OF_POINT_16_30

LEVEL_OF_POINT_16_30

Level table

Level table

Level table

Level table

RW

Table entries 16-30 containing level values.

LIN_TYPE

LIN_TYPE

LIN_TYPE

LIN_TYPE

Linerization Type

Linerization Type

Linerization Type

Linerization Type

R

The linerization type used to describe the behavior of the

sensor output.

linear with

input

Setting:

Linear with input

MEASURE_THRESHOLD

MEASURE_THRESHOLD

MEASURE_THRESHOLD

MEASURE_THRESHOLD

Measurement threshold

Measurement threshold

Measurement threshold

Measurement threshold

RW

If it is difficult to identify the level signal (for example: too

many parasite signals) you can increase the threshold of the

signal. A threshold of 1000 is equivalent to the amplitude of

the measurement pulse. A threshold of 100 is equivalent to

10% of the amplitude of the measurement pulse.

MINIMUM_LAYER

MINIMUM_LAYER

MINIMUM_LAYER

MINIMUM_LAYER

Interface Minimum Layer

Interface Minimum Layer

Interface Minimum Layer

Interface Minimum Layer

RW

Interface Minimum Layer

OFFSET

OFFSET

OFFSET

OFFSET

Offset

Offset

Offset

Offset

RW

Offset

OVERFILL_ERROR

OVERFILL_ERROR

OVERFILL_ERROR

OVERFILL_ERROR

Overfill Error

Overfill Error

Overfill Error

Overfill Error

RW

Overfill Error Alarm

Setting:

Warning / Error

POINTS_NUM

POINTS_NUM

POINTS_NUM

POINTS_NUM

Number of table entries

Number of table entries

Number of table entries

Number of table entries

RW

Number of entries in the conversion table for mass/volume.

Setting:

0...30

PRIMARY_VALUE_TYPE1

PRIMARY_VALUE_TYPE1

PRIMARY_VALUE_TYPE1

PRIMARY_VALUE_TYPE1

Primary Value Type

Primary Value Type

Primary Value Type

Primary Value Type

R

The type of measurement represented by the primary value.

For Example: Mass Flow, Absolute Pressure, Differential

Temperature.

level

Parameter

Parameter

Parameter

Parameter
DD name

Access Description and settings

Initial Value