beautypg.com

Technical data – KROHNE UFM 530 HT EN User Manual

Page 64

background image

8

TECHNICAL DATA

64

UFM 530 HT

www.krohne.com

12/2013 - 4002393201- HB UFM 530 HT R02 en

Current output

Current output

Current output

Current output

Function / output data

Measurement of volume flow rate, velocity of sound, signal strength,

flow direction.

Settings

Q = 0%: 0...16 mA
(HART

®

versions: 4...16mA, in steps of 1 mA, limit 20...22 mA).

Q = 100%: 4...20 mA.

Operating data / Connection

Active mode: U

int

= 24 VDC, maximal load: 680 Ω.

Passive mode: U

ext

≤ 24 VDC, maximal load: 680 Ω.

Pulse output

Pulse output

Pulse output

Pulse output

Function / output data

Measurement of volume flow rate, actual volume, velocity of sound,

signal strength, flow direction.

Settings

Calculated mass flow rate.

Pulse or frequency: 0...2000 Hz, status: on/off.

Operating data / Connection

Active mode: U

int

= 24 VDC, I

max

= 50 mA.

Passive mode: U

ext

= 19...32 VDC, I

max

= 150 mA.

Analog inputs

Analog inputs

Analog inputs

Analog inputs

Function / output data

Inputs for calculated (or user defined) mass flow rate.

Settings

For both inputs (A1 and A2): 4...20 mA.

Operating data / Connection

Active mode: I

max

= 22 mA, maximal load: 58 Ω.

Passive mode: I

max

= 22 mA, maximal load: 58 Ω.

Digital input

Digital input

Digital input

Digital input

Function / output data

Reset totalised volume, reset errors, force outputs to zero.

Settings

On/off

Operating data / Connection

Active mode: U

max

≤ 24 VDC.

Passive mode: U

max

≤ 24 VDC.

Approvals

CE

See section 1.3.1.

Hazardous areas

Hazardous areas

Hazardous areas

Hazardous areas

Ex zone 1

According to European Directive 94/9 EC (ATEX 100a).

FM Div. 1

Approval number 3016332

CSA

Approval number 1515313

Protection category according to IEC 529 / EN 60529

Protection category according to IEC 529 / EN 60529

Protection category according to IEC 529 / EN 60529

Protection category according to IEC 529 / EN 60529

Sensor

IP65 eq. NEMA 4 / 4X

INFORMATION!
Other diameters, pressure classes or materials than the above-mentioned on request.