beautypg.com

Installation, 4 inlet and outlet – KROHNE UFM 530 HT EN User Manual

Page 13

background image

INSTALLATION

3

13

UFM 530 HT

www.krohne.com

12/2013 - 4002393201- HB UFM 530 HT R02 en

3.4 Inlet and outlet

INFORMATION!
To avoid measuring errors and to get proper measuring results an inlet section upstream and an
outlet section downstream is necessary. Regard the following illustration and table and regard
the information for different fluid products:

Figure 3-2: Recommended straight inlet and outlet

1 DN25...80: ≥ 50 DN

DN100...300: ≥ 15 DN

2 DN25...80: ≥ 10 DN

DN100...300: ≥ 5 DN

INFORMATION!
Different fluid products

Different fluid products

Different fluid products

Different fluid products
To mix different fluid products, install the flow meter upstream of mixing point or at minimum
distance of 30 DN downstream of the mixing point.