beautypg.com

Technical data – KROHNE UFM 530 HT EN User Manual

Page 62

background image

8

TECHNICAL DATA

62

UFM 530 HT

www.krohne.com

12/2013 - 4002393201- HB UFM 530 HT R02 en

Display functions

Display functions

Display functions

Display functions

Menu

Display of volume flow, mass flow, flow speed, velocity of sound, gain,

signal to noise ratio, diagnosis value, forward, reverse and

counters,warning and diagnosis information, setting parameters via

operating menu

Language of display texts

English, French, German

Measuring accuracy

Reference conditions

Reference conditions

Reference conditions

Reference conditions

Medium: water

Temperature: 20°C

Pressure: 1 bar

Inlet section: 10 DN

Maximum measuring error

±

1% of the measured value for Re > 5000 and v = 1...20 m/s

(3.28...65.62 ft/s), temperature influence: 0.1% / 10 K.

±

1 cm/s at v < 1 m/s (±0.39"/s at v < 3.28 ft/s)

Repeatability

±

0.3%

Calibration

2-point, water, under reference conditions.

Operating conditions

Temperature

Temperature

Temperature

Temperature

Process temperature

Standard version: -25...+500°C / -13...+932°F

Ex version: -25...+440°C / -13...+824°F

Ambient temperature

(signal converter)

-40...+65°C / -40...+149°F

Storage temperature

(signal converter)

-40...+70°C / -40...+158°F

Pressure

Pressure

Pressure

Pressure

Ambient

Atmospheric

EN 1092-1

DN200...300: PN10

DN100...150: PN16

DN25...80: PN40

Higher pressure ratings on request

ASME B16.5

1...12": 150 lbs

Higher pressure ratings on request

JIS

10K

Medium properties

Medium properties

Medium properties

Medium properties

Physical condition

Liquids

Permissible gas content (by

volume)

<2%

Permissible solid particle

content (by volume)

<5%

Viscosity

<100 cSt

Higher viscosities on request

Recommended flow velocity

0.5...20 m/s / 1.7...66 ft/s