beautypg.com

Installation – KROHNE UFM 530 HT EN User Manual

Page 16

background image

3

INSTALLATION

16

UFM 530 HT

www.krohne.com

12/2013 - 4002393201- HB UFM 530 HT R02 en

Figure 3-7: Air vent

1 Level difference > 5 m / 16 ft
2 Install an air vent.

Figure 3-8: Install control valve downstream of the flow meter.

Figure 3-9: Install pump upstream of flowmeter.

Figure 3-10: Avoid installation in vibrating pipelines.