Device description, 2 device description, 3 nameplates – KROHNE UFM 530 HT EN User Manual
Page 10
2
DEVICE DESCRIPTION
10
UFM 530 HT
www.krohne.com
12/2013 - 4002393201- HB UFM 530 HT R02 en
2.2 Device description
The UFM 530 HT is a bi-directional flowmeter (the arrow on the flowmeter indicates the positive
direction). It consists of a UFS 500 HT flow sensor and an UFC 030 signal converter.
The signal converter is installed separately from the high-temperature flow sensor.
The flow sensor is designed for process temperatures between -25...+500°C / -13...+932°F (Ex
hazardous areas are limited to -25...+440°C / -13...+824°F) and is manufactured from
316 stainless steel. Depending on the diameter it uses single beam or dual beam technology. All
coax cables are protected with metal tubes. On top of the flow sensor a connection box is
mounted.
2.3 Nameplates
INFORMATION!
Other diameters, pressure classes, materials or customized designs are available on request.
Figure 2-2: Available sensor versions
1 Building construction "single beam" (DN25...40)
2 Building construction "single beam" (DN50...80)
3 Building construction "dual beam" (≥DN100)
INFORMATION!
Look at the device nameplate to ensure that the device is delivered according to your order.
Check for the correct supply voltage printed on the nameplate.