ANALOG REMOTE MODE PROGRAMMING

The BOP can be programmed remotely using analog signals applied to the remote Analog I/O
port at the rear panel (see Figure 2-1 and Table 2-10). Analog remote programming allows the
user to 1) establish voltage or current mode (PAR. 3.4.2), 2) control the main channel using the

Save Disabled, Request ignored

Save Display Change is disabled. From power-up screen, press

%

, highlight password

settings to enable.

EXTERNAL MODE enabled.

MODE key does not function while Mode is being controlled externally. Press

$

, high-

light External Mode and change to Disable.

F2 Key not valid

F2 only works when labeled. key was probably pressed inadvertently.

Password incorrect

Enter the correct password and press

!

. If password has been lost and can not be

recovered, refer to PAR. 3.6.3.12.1 to reset to factory defaults.

Setup Menu

F3 - Invalid

#

only works when labeled. Key was probably press inadvertently.

F4 - Invalid

$

only works when labeled. Key was probably press inadvertently.

Master/Slave Menu

Series or Parallel when not
STANDALONE

Mismatch between Unit type and Connection type. Automatically reverts to
Unit type: Standalone, Connection Type: standalone.

Calibration invalid - Multiple Unit

Consult Factory.

BITBUS option must be Disabled

Change CIIL mode to SCPI. From power-up screen press

%

highlight Interface Data For-

mat, press

!

, highlight SCPI, press

$

, then press

$

to save for power-up, then

cycle BOP off, then on.

Waveform Menu

External Reference Waveform not
accessible

Reference Input must be set to Internal for waveforms to be executed. Press

$

highlight

Reference Input, press

!

highlight Internal, press

$

, then

%

.

External Mode - Waveform not
accessible

External Mode must be disabled for waveforms to be executed. Press

$

highlight Exter-

nal Mode, press

!

highlight Disable, press

$

, then

%

.

External Limits - Waveform not
accessible

Protection Limit must be set to Internal for waveforms to be executed. Press

$

highlight

Protection Limit, press

!

highlight Internal, press

$

, then

%

.

Empty Entry - use F2 instead

Empty location cannot be modified using

!

Press

@

to start new waveform.

No Room to insert - delete a segment. No more than 10 segments are allowed in a waveform.

Unable to delete segment.

Try again. If still unable to delete segment, contact factory. for RMA.

Only EDIT allowed on Entry.

When viewing waveform, if name, count or protection levels are highlighted, press

!

to

modify the setting.

@

and

!

are not functional with these parameters.

MODE incorrect - Please Change

A voltage waveform was executed while the unit was in current mode or a current
waveform was executed while the unit was in voltage mode. Press MODE key to change to
correct mode, press STANDBY key to set output on then press

$

to run the waveform

Unit in STANDBY - Please Change

Output must be on for the waveform to be executed. press STANDBY key to set output on
then press

$

to run the waveform

Can not delete Single Segment - use
F1 to Change

Waveform must have at least one segment.

Can not delete the empty segment.

“End of Segments” was highlighted when

#

- Erase was pressed. Move highlight to valid

segment and try again.

Entry not Empty, Use F1 to change.

@

pressed while a previously saved waveform was highlighted. Use

!

to modify or

highlight Empty and press

@

for a new waveform.

Under Minimum allowed value

Frequency or period was too small.

Frequency has no sign

+/- key is not functional when modifying frequency.

Use F5 to stop waveform.

$

not valid when waveform already executing.

TABLE 3-13. ERROR MESSAGE EXPLANATIONS (CONTINUED)

ERROR MESSAGE

EXPLANATION