1-8

BOP HIPWR 080709

SAVE/RECALL CHARACTERISTICS

(See PAR. 3.3.8)

Number of Locations

99

Parameters Saved or Recalled

All parameters saved for power-up.

Mode of operation

Voltage, Current or External

For External the operating mode is deter-
mined by signal at I/O Port; no signal selects
voltage mode (see PAR. 3.4.2).

Reference type

Internal, External or

External Reference Level

Main channel

Internal, External or

Lesser Limit

Limit channel

Main Amplitude

(Internal)

0 to EO

NOM

or IO

NOM

(internal or external)

Main Channel:
Voltage (Volts) for Voltage mode,
Current (Amperes) for Current mode

Protection Limit Amplitude

(Internal)

EO

MIN

or IO

MIN

to

1.01 EO

NOM

or IO

NOM

Limit Channel, Positive and Negative
Voltage (Volts) for Current mode,
Current (Amperes) for Voltage mode

Output status

ON or OFF

MISCELLANEOUS FEATURES

Maximum/Minimum Settings

Protection Limit

Type

Bipolar (default) or Independent

Main Channel

0 to EO

NOM

or IO

NOM

(default)

Software limit to setting of main channel
Voltage (Volts) for Voltage mode,
Current (Amperes) for Current mode

Protection Limit Channel

(maximum value, Internal)

EO

MIN

or IO

MIN

to

1.01 EO

NOM

or IO

NOM

(internal)

Software limit to setting of protection limit
channel.
Voltage (Volts) for Current mode
Current (Amperes) for Voltage mode

Load Type Settings

Active (default), Resistive,

Battery, Custom

Consult factory for custom setting.

Self-test capabilities

Display, Keypad, Interface, Serial

Interface, Analog, Output

Serial Interface test requires Loop Back Test
connector (p/o KIT 219-0436, see Table 1-5).

Interface Settings

Data Format

SCPI (default), CIIL

GPIB Address

0 to 30 (6 = default)

Output Status @ Reset

ON or OFF (OFF = default)

Serial Baud Rate

Off, 9600, 19200 (Off = default)

Device Clear

SCPI (default) or MATE

XON/XOFF

Enable (default) or Disable

Prompt

Disable (default), Enable,

Enable with Echo

Calibration

Assisted by front-panel prompts

TABLE 1-2. BOP GENERAL SPECIFICATIONS (Continued)

SPECIFICATION

RATING/DESCRIPTION

RATING/DESCRIPTION