KEPCO BOP 1KW-MG Operator Manual, Firmware Ver.2.38 to 2.47 User Manual

Page 24

background image

1-4

BOP HIPWR 080709

PROGRAMMING/DISPLAY CHARACTERISTICS

Analog I/O Port
(See Table 2-10)

Main

channel

(voltage or current)

–10V to +10V

Full range output, 20K Ohm input impedance
(see PAR. 3.4)

Protection Limit

channels:

(±Voltage, ±Current)

+1V to +10V

10% to 100% of Nominal Range. Input voltage
clamped to 12V through 1K ohms. Maximum
of 0.15mA input current at1V input voltage.

Mode Control

Voltage: open circuit or TTL logic 1
Current: short circuit or TTL logic 0

Available only when digitally activated through
Power-up setting..

Output Current

Analog Readback

0 to ±10 Volts corresponds to zero to

± Full Scale nominal output current

Output impedance of this signal is 2K Ohms.

External Protection Port
(see Table 2-4)

External Shutdown

Isolated input for shutdown of the

BOP (latched status)

Pulse width: 100 microseconds min.
Action delay: 100 microseconds max
Restore operation by cycling input power or
pressing RESET key.

External Shutdown

Flag

Isolated output indicating

shutdown status)

Action delay: 100 microseconds max

External On-Off

Flag

Isolated output indicating

output on (enabled, STANDBY off) or

off (disabled, STANDBY on) status)

Action delay: 200 milliseconds max

Trigger Port
(See Table 2-3)

External Trigger

Shutdown

Isolated input for setting the BOP

in STANDBY (output off)

(latched status)

Pulse width: 100 microseconds min.
Action delay: 200 milliseconds max
Restore operation by pressing STANDBY key.
or sending OUTP ON command via remote
interface.

External Trigger

Input

Isolated input for trigger events

Pulse width: 100 microseconds min.
Action delay: 500 microseconds max

Digital control

local

Panel-mounted keypad

Direct Entry

remote

IEEE 488-2 (GPIB)

SCPI

remote

RS 232

remote

RS 485 (BITBUS)

IEEE 1118

Display

front panel

4" backlit LCD displays all functions

remote

All parameters read back on GPIB or RS 232 buses

FUNCTION GENERATOR CHARACTERISTICS

(See PAR. 3.3.9)

Maximum number of waveforms

Local: 16

Remote: 1

Local: Saved for power-up
Remote: Lost when the unit is turned off, must
be saved on the host computer)

Maximum number of segments or basic wave-
forms per waveform

Local: 10

Remote: 126

Or maximum number of points (whichever
comes first)
• The time interval for each segment

depends on the type of waveform: period
for ramp and square waveforms, period or
fraction of period for sine and triangular
waveforms and time interval for DC levels

• Segments that cause the waveform to

exceed the maximum number of points are
not executed. For local operation they are
marked with a triple asterisk on the front
panel. For remote operation an error mes-
sage is generated.

TABLE 1-2. BOP GENERAL SPECIFICATIONS (Continued)

SPECIFICATION

RATING/DESCRIPTION

RATING/DESCRIPTION