Table 2-1. controls, indicators, and connectors, Controls, indicators, and connectors -2, E 2-1 – KEPCO BHK-MG 40W (Half Rack) Series User Manual

Page 32

background image

2-2

BHK-1/2-MG SERIES 121313

TABLE 2-1. CONTROLS, INDICATORS, AND CONNECTORS

CONTROL, INDICATOR,

CONNECTOR

FUNCTION

FRONT PANEL (See Figure 2-1.)

A-C line indicator

Lights to indicate unit turned on and a-c power applied.

LCD

2 x 16 character Liquid Display with LED backlight. Shows voltage, current
mode, settings, menu, program, etc.

Keypad

24 keys used for local operation of the power supply; Refer to Table 3-2 for
details.

POWER circuit breaker

Circuit breaker used to turn unit on and off.

Output jack

Provide front panel access to d-c output of power supply.

REAR PANEL (See Figure 2-2.)

IEEE 488 PORT

24-pin GPIB connector used to connect to GPIB bus (see Table 2-2 for pin
assignments).

STATUS AND REMOTE ON/OFF PORT

Notifies host computer either that a-c input is not present or a major failure of
power supply has occurred and allows remote on/off control of the unit (see
Table 2-3 for pin assignments).

RS 232 PORT

8-pin connector telephone jack type used to connect to RS 232 bus. Adapter
cable kit (see Table 1-5) converts to 9-pin jack (see Table 2-4 for 9-pin assign-
ments).

EXTERNAL TRIGGER PORT

4-pin connector used to restore previously stored settings or to shut down the
output (see Table 2-5 for pin assignments). NOTE: Mating connector is a 3-pin
plug.

OUTPUT TERMINALS barrier strip TB1

(See NOTE 1.)

Provides Power Supply output connection points. (See Table 2-6 for terminal
assignments)

V PROG terminal strip TB2

(See NOTE 1.)

Provides input/output signals for analog programming of output voltage or volt-
age limit. (See Table 2-7 for terminal assignments.)

I PROG terminal strip TB3

(See NOTE 1.)

Provides input/output signals for analog programming of output current or cur-
rent limit. (See Table 2-8 for terminal assignments.)

AC SELECTOR switch

Used to select between nominal input line voltage of 115 V a-c or 230 V a-c.

AC INPUT connector

Provides a-c source power to unit.

Terminal Drawer Closed detector

(see NOTE 2.)

Provides protection when Terminal Drawer is open by tripping the a-c circuit
breaker to off.

NOTES 1. Accessible by loosening two captive screws and pulling out terminal drawer, and removing protective insulator (see

Figure 2-2).

2. The Terminal Drawer detector (located on PC board A3) and the a-c circuit beaker function as an interlock switch.