B-21/(b-22 blank), Table b-4. error messages (continued) – KEPCO BHK-MG 40W (Half Rack) Series User Manual
Page 147

BHK-MG 1/2 (OPR) 121313
B-21/(B-22 Blank)
-282,”Illegal program
name”
Execution error bit 4
Executing prog:run without LIST:SEQ command
-301,”Value bigger than
limit”
Device Error bit 3
(1)
Requesting a time of 656 which is bigger than limit
-311,”Memory error”
Device Error bit 3
(1)
Power-up NV RAM error
-314,”Save/recall
memory error”
Device Error bit 3
(1)
Using cell other than 1 - 41 for SAV and RCL
-341,”Non Volatile
Mem. CRC error”
Device Error bit 3
(1)
Power supply constants may be corrupted; recalibration may be neces-
sary.
-350,Queue overflow
Device Error bit 3
(1)
More than 15 errors are in queue.
-410,”Query
interrupted
Query Error bit 2
New command sent before data from previous query read. Previous
query data lost.
-430,Query Deadlocked
Query Error bit 2
Over 255 characters received in single input string.
(1)
The Device error bit may be set when the status monitoring functions of the power supply detect an overvoltage/undervolt-
age condition.
TABLE B-4. ERROR MESSAGES (CONTINUED)
ERROR MESSAGE
ESR ERROR BIT SET
(SEE PAR. A.5)
EXPLANATION