KEPCO BHK-MG 40W (Half Rack) Series User Manual
Page 112

3-68
BHK-1/2-MG 121313
3. Program slave unit as follows:
a. Program output current of slave unit (Iset
S
) to 0.
b. Program Vset
S
to the rated maximum voltage of the slave unit, E
O
max
S
(e.g., for
BHK1000-40MG set Vset
S
= 1000).
c. Program overcurrent value of slave unit (Iocset
S
) to 1.1 x rated maximum current of
slave unit, I
O
max
S
(e.g., for BHK 1000-40MG, program Iocset
S
= 44 (mA)).
d. Program overvoltage value of slave unit (Vovset
S
) to 1.1 x voltage limit E
LIM
desired for
power assembly.
4. Program master unit as follows:
a. Program Iset
M
to 1/2 the desired output current, Io, of the power assembly.
b. Program Vset
M
to the voltage limit, E
LIM
desired for power assembly.
c. Program overcurrent value of master unit (Iocset
M
) to 1.1 x Iset
M
(step 4a).
d. Program overvoltage value of master unit (Vovset
M
) to 1.1 x Vset
M
(step 4b).
5. To apply power to the load:
a. If load switch used, open the switch.
b. If load switch not used, press POWER ON/OFF key once on slave unit, then once on
master unit.
6. To disable power to the load:
a. If load switch used, close the switch.
b. If load switch not used, press POWER ON/OFF key once on master unit, then once on
slave unit.
c. Alternative: Turn both units off by setting POWER switch to off (down) position, first on
master unit, then on slave unit.