2.9 STATus subsystem

GW APS-1102 STAT Cond.vi
This returns the operation condition register (OPCR). The response range is 0 to 20482.

OPCR

This outputs the operation condition register (OPCR).

GW APS-1102 STAT Enab.vi
This sets the operation event enable register (OPEE). The setting range is 0 to 20482.

OPEE set

This sets the operation event enable register (OPEE). The default setting is “0”.

OPEE

When Read = True, queries contents of the operation event enable register (OPEE) set for the
APS-1102. When Read = False, “99999” is set.

GW APS-1102 STAT Oper.vi
This returns the operation event register (OPER) value. The response range is 0 to 20482.

OPER

This outputs the operation event register (OPER) value.

GW APS-1102 STAT Ntr_Ptr.vi
This sets the operation transition filter (OPTF). The setting range is 0 to 20482.
 When the NTR filter is set to 1, OPER is set to 1 when OPCR changes from 1 to 0.
 When the PTR filter is set to 1, OPER is set to 1 when OPCR changes from 0 to 1.
 When the NTR and PTR filters are both set to 1, OPER is set to 1 when OPCR changes.
 When the NTR and PTR filters are both set to 0, changes in OPCR are not propagated to OPER.

NTR set

This sets the NTR filter. The default setting is “0”.

PTR set