2.4

VISA

Initialization

2-5

Low_Rn200V [A]

This sets the upper limit of the output peak current (negative polarity) in the 200 V range.
The default setting is “–21.0”.

Rn_set

This specifies the range to be set. The default setting is “100V (False)”.

Output [A]

When Read = True, outputs the upper limit of the output peak current (negative polarity) set
for the APS-1102. When Read = False, “–99.9” is set.

GW APS-1102 SOUR Freq.vi
This sets the output frequency. In the AC-EXT, AC-SYNC, AC+DC-EXT, or AC+DC-SYNC mode,

frequency setting is disabled. ([3,"Invalid in this mode"] error occurs.)

Frequency [Hz]

This sets the output frequency. The default setting is “1.0”.

Output [Hz]

When Read = True, outputs the output frequency set for the APS-1102. When Read = False,
“9999.9” is set.

GW APS-1102 SOUR Freq High.vi
This sets the upper limit of the frequency that can be set. However, a value that is at or below the

currently set frequency cannot be set. ([5,"Out of Limiter"] error occurs.)

Limit Frequency High [Hz]

This sets the upper limit of the frequency. The default setting is “550.0”.

Output [Hz]

When Read = True, outputs the upper limit of the frequency set for the APS-1102. When
Read = False, “9999.9” is set.

GW APS-1102 SOUR Freq Low.vi
This sets the lower limit of frequency that can be set. However, a value that is at or above the

currently set frequency cannot be set. ([5,"Out of Limiter"] error occurs.)