5 - connecting speaker/amplifiers, 6 - connecting external initiating inputs, External inputs – Edwards Signaling 5541M-Y6 User Manual
Page 11
![background image](/manuals/367105/11/background.png)
P/N 3100471 ISSUE 3
PAGE 11
MAIN ADJ
MAIN OUT
POWER
SUPERVISION
+
-
+
-
TB11
TB8
+TX/RX -TX/RX
TB10
AUD + AUD -
A
B
10V RMS
Audio (or
5V RMS for
live voice evac)
5532M Series Audio Coupler Board
For detailed installation of 5532M
Series Speaker Amplifiers, refer
to the instructions supplied with
the unit.
End-of-line resistor - 2.2K
Cat. No. EOL-2.2
NOTE: Do NOT use test
resistor (supplied) installed
on the MAIN OUT terminal
(-)
(+)
For systems with 5532M-485 Series Speaker/Amplifers installed,
To TX/RX terminals on RS485 comm board on 5532M speaker/amp
AUD + AUD -
A
B
AUD + AUD -
A
B
AUD + AUD -
A
B
RS485 COMM
Board
Potentiometer for
Volume Adjustment
Processor Board
EARTH
-RELAY
+RELAY
-TX/RX
+TX/RX
Figure 7. Connecting 5532M Series Speaker/Amplifiers to Audio Main Out
5532M-485
Assembly
2.5 - Connecting Speaker/Amplifiers
The Millennium System Master is capable of driving a total of 200
(64 of which can be addressable) 5532M Series speaker/amplifiers.
Connect the console to the speaker/amplifiers as described below
(See Figures 3 and 7).
1.
Connect 10V RMS audio line (or 5V RMS for live voice
evacuation) from "Main Out" (terminal block TB10) to the first
5532M speaker/amplifier. For connections to the 5532M
speaker/amplifier, refer to the instructions supplied with the
unit.
2.
Continue to connect remaining 5532M series speaker/
amplifiers as shown in Figure 7 ending the loop with a 2.2K
end-of-line resistor (Part Number EOL-2.2).
3.
For 5532M-485 Series speaker/amplifiers, connect the RS485
wire from +TX/RX (TB10) on the console board to terminal
+TX/RX on the RS485 COMM board. Connect the RS485 wire
from -TX/RX (TB10) on the console board to -TX/RX on the
RS485 COMM board. For further installation details for 5532M-
485 series, refer to installation instructions P/N 3100345.
2.6 - Connecting External Initiating Inputs
The initiating contacts operate on a pyramid-type priority system.
Output from a contact closure on Input 1 overrides the output from
a contact closure on Inputs 2, 3 and 4. The output from a contact
closure on Input 2 overrides the output from a contact closure on
Inputs 3 and 4. Likewise, the output from a contact closure on
Input 3 overrides the output from a contact closure on Input 4. The
output from a contact closure on Input 4 cannot override the out-
put from any other external input.
1.
Remove all test resistors from the input terminals. Install 4.7K
ohm resistors, Cat. No. EOL-4.7, on terminals that will not have
initiating contacts connected to them.
2.
Connect normally-open initiating contact(s) to input terminals
IN1, IN2, IN3, IN4 on External Input terminal block, TB14 (see
Figures 3 and 8) as required. Install 4.7K ohm resistors, Cat.
No. EOL 4-7, at the end of each circuit as shown in Figure 8.
NOTE: If connecting an external input to a Fire Alarm Panel, refer to
Section 2.8.
Figure 8. Connecting Normally-Open Initiating Contacts
In
Out
In
Out
Correct--separate incoming and outgoing conductors
Incorrect Wiring Method
EXTERNAL INPUTS
IN1
IN2
IN3
IN4
TAM
1
2
3
4
5
6
7
8
9
10
TB14
Normally-open
initiating contacts
End-of-line resistor 4.7K
Cat. No. EOL-4.7
Pri 1
Pri 2
Pri 3
Pri 4