Engl ish – Spectra Precision ProMark Field Software User Manual
Page 59

Engl
ish
53
See table below.
NOTE: You can create as many NTRIP and Direct IP
configurations as necessary. Each configuration can be
recalled by just selecting its name (
Name field). A recalled
configuration may be deleted by tapping on the
Del
button.
• Tap on the
Format tab and choose the format of the
corrections the base will generate and deliver (Eight
possible choices: RTCM3.0, RTCM2.3 (DGPS), RTCM2.3
(RTK), CMR, CMR+, ATOM, ATOM compact or ATmOM
super compact).
• Tap on the
Station tab: Enter the Station ID for the base.
This number is left to the user’s choice but the following
ranges of
Station ID values are recommended depending on
the selected data format:
•
Recording tab: Although operated as an RTK base, the
receiver can also collect raw data. In that case, enable the
Record raw data for post-processing function, check that you
are using the desired storage medium (it is a good practice
to use a Storage Card) and choose the recording interval
(default: 1 second).
Device
Settings
UHF radio
Type, baud rate, advanced
GSM (CSD) modem None
Network connection
via GSM (GPRS)
modem
Direct IP parameters:
• Name, host, port
Or NTRIP parameters:
• Name, host, port
• Password, station
External cell phone
via Bluetooth
See Handheld Platform for ProMark Getting Started
Guide, Advanced Features section.
Other external device Port, baud rate
Format
Station ID
RTCM 3.0
0-4095
RTCM2.3
0-1023
CMR, CMR+ 0-31
ATOM
0-4095