Lincoln Electric IM8001 PRODUCTION MONITORING 2.2 User Manual
Page 89

Chapter 5. Using Production Monitoring™
Production Tab
5.16
Production Monitoring™ User Manual
IM8001
Table 5.7
Columns on the WeldScore™ Report
Column
Description
Period
The Period column reflects the choice made in the Group Welds drop-down on the
Criteria window, as well as the Start Date/End Date range and Shift selected.
To generate a new, more detailed report for a specific Period in the report, click the
link. The system automatically generates the WeldScore™ report on the Welding
Listing tab for you (page 5.25).
WeldScore™ (%)
The system averages all WeldScore™ data for the Welding Power Source or Group of
power sources you have selected in the Asset Tree and displays that average score in
this column.
Current/Voltage Report
If you need to review the electrical output of a specific Welding Power Source on the production floor, the
Current/Voltage report provides you with a graph that displays both the current and the voltage in the
same graph. This allows you make see any adjustments you might need to make.
NOTE |
This report is only available for a single Welding Power
Source.
Figure 5.16 Production Report: Current/Voltage