Lincoln Electric IM8001 PRODUCTION MONITORING 2.2 User Manual
Page 86

Production Tab
Chapter 5. Using Production Monitoring™
IM8001
Production Monitoring™ User Manual
5.13
Column
Description
Avg. Current
Every weld has an average current value that was measured throughout the
duration of the weld. The system takes that averaged value for each weld that
was performed during the time period displayed in the Period column, totals
them and displays that average in the Avg. Current column.
Avg. Voltage
Every weld has an average voltage value that was measured throughout the
duration of the weld. The system takes that averaged value for each weld that
was performed during the time period displayed in the Period column, totals
them and displays that average in the Avg. Voltage column.
Avg. WFS
Every weld has an average wire feed speed value that was measured throughout
the duration of the weld. The system takes that averaged value for each weld
that was performed during the time period displayed in the Period column, totals
them and displays that average in the Avg. WFS column.
Avg. True Energy
For each weld in the time period displayed in the Period column, there is a True
Energy™ value. The Avg. True Energy displays the average of those values.
Weld Profiles Report
The Weld Profiles report is useful when monitoring the performance of the Weld Profiles in use on the
selected power source. Within these profiles, Weld Engineers set various limits for the weld. If the weld
goes above or below those limits, the system records that information as “out of limits”. (For more details
on managing Weld Profiles, please see the Power Wave® Manager User Manual.)
NOTE |
If a Weld Operator did not choose a Weld Profile for a weld,
the Welding Power Source automatically assigns the weld
to the last profile. For those power sources utilizing 32
profiles, this is Profile 32. For those utilizing 200 profiles,
the weld is assigned to Profile 200.
The Weld Profiles report is the only Production report that has a limited set of criteria available to you. All
others have the full set of criteria.
NOTE |
This report is only available for a single Welding Power
Source.