User computer requirements, Power wave® requirements, Voltage – Lincoln Electric IM8001 PRODUCTION MONITORING 2.2 User Manual
Page 123: Current

Appendix A. Additional Information
Archive of Data from the Database
A.6
Production Monitoring™ User Manual
IM8001
Column Heading
Description
Voltage
VAvgValue
Hundreds of times per second, the Welding Power Source takes a
measurement of the arc voltage while the welder is active for this weld.
When the weld is complete, the power source averages those measurements
together. The VAvgValue column displays that average arc voltage value for
this weld.
VMinValue
The VMinValue column is the lowest arc voltage measurement taken by the
Welding Power Source throughout the duration of this weld.
VMaxValue
The VMaxValue column is the highest arc voltage measurement taken by the
Welding Power Source throughout the duration of this weld.
VLowPercent
This value is the percentage of measurements taken during the weld that
were below the arc voltage limit set in the Weld Profile used to make this
weld.
VHighPercent
This value is the percentage of measurements taken during the weld that
were above the arc voltage limit set in the Weld Profile that was used to
make this weld.
VLowLimit
This column simply displays the low end of the voltage limit that was set in
the Weld Profile used to make the weld.
VHighLimit
The value in this column is the high end of the voltage limit that was set in
the Weld Profile used to make the weld.
VIsLow
If the average voltage used to make the weld fell below the low end of the
limit set for the Weld Profile that was used, the value in the VIsLow column
will be 1. Otherwise, the value will be 0.
VIsHigh
If the average voltage used to make the weld was above the high end of the
limit set for the Weld Profile that was used, the value in the VIsHigh column
will be 1. Otherwise, the value will be 0.
VBaseUnits
The VBaseUnits column simply displays the voltage units used in this weld
record. Typically, this is set to V for “volts”.
Current
CAvgValue
Hundreds of times per second, the Welding Power Source takes a
measurement of the arc current while the welder is active for this weld.
When the weld is complete, the power source averages those measurements
together. The CAvgValue column displays that average arc current value for
this weld.
CMinValue
The CMinValue column is the lowest arc current measurement taken by the
Welding Power Source throughout the duration of this weld.