Network requirements, System limitations, ݎݑ݁ ܧ݊݁ݎ݃ݕ [ ܬ – Lincoln Electric IM8001 PRODUCTION MONITORING 2.2 User Manual
Page 124: Wire feed speed

Archive of Data from the Database
Appendix A. Additional Information
IM8001
Production Monitoring™ User Manual
A.7
Column Heading
Description
CMaxValue
The CMaxValue column is the highest arc current measurement taken by the
Welding Power Source throughout the duration of this weld.
CLowPercent
This value is the percentage of measurements taken during the weld that
were below the low end of the arc current limit set in the Weld Profile that
was used to make this weld.
CHighPercent
This value is the percentage of measurements taken during the weld that
were above the high end of the arc current limit set in the Weld Profile that
was used to make this weld.
CLowLimit
This column simply displays the low end of the arc current limit that was set
in the Weld Profile used to make the weld.
CHighLimit
This column simply displays the high end of the arc current limit that was set
in the Weld Profile used to make the weld.
CIsLow
If the average current used to make the weld fell below the low end of the
limit set for the Weld Profile that was used, the value in the CIsLow column
will be 1. Otherwise, the value will be 0.
CIsHigh
If the average current used to make the weld was above the high end of the
limit set for the Weld Profile that was used, the value in the CIsHigh column
will be 1. Otherwise, the value will be 0.
CBaseUnits
The CBaseUnits column simply displays the arc current units used in this weld
record. Typically, this is set to A for “amps”.
Wire Feed Speed
WFSAvgValue
Hundreds of times per second, the Welding Power Source takes a
measurement of the speed at which the wire is put into the weld. When the
weld is complete, the power source averages those measurements together.
The WFSAvgValue column displays that average wire feed speed value for
this weld.
WFSMinValue
The WFSMinValue column is the lowest wire feed speed measurement taken
by the Welding Power Source throughout the duration of this weld.
WFSMaxValue
The WFSMaxValue column is the highest wire feed speed measurement
taken by the Welding Power Source throughout the duration of this weld.
WFSLowPercent
This value is the percentage of measurements taken during the weld that
were below the wire feed speed limit set in the Weld Profile that was used to
make this weld.
WFSHighPercent
This value is the percentage of measurements taken during the weld that
were above the wire feed speed limit set in the Weld Profile that was used to
make this weld.