beautypg.com

2 most recent (do channel) status (frelay), 2 most recent (do channel) status (frelay) -58, For the output format, see – Yokogawa Touch Screen GP20 User Manual

Page 72

background image

2-58

IM 04L51B01-17EN

V_¯_¯_¯_¯_ V

^C_¯_¯_¯_¯ °C

f

Sign (+ or -)

dddddddd

Mantissa (00000000 to 99999999; 8 digits)

For erroneous data (data status is E), the mantissa is 99999999.

If the data status is O (±over), the mantissa is 99999999 (+over) or

–99999999 (–over).

If the data status is B (burnout), the mantissa is 99999999 (+burnout) or

–99999999 (–burnout).

pp

Exponent (00 to 05)

2.10.2 Most Recent (DO Channel) Status (FRelay)

The output in response to the command “FRelay,0” is shown below.

Syntax

EA

M00:aaa…

M01:aaa…

M02:aaa…

M03:aaa…

M04:aaa…

M05:aaa…

M06:aaa…

M07:aaa…

M08:aaa…

M09:aaa…

EN

aaa…

Outputs the relay (DO channel) status of module numbers 00 to 09.

If the module installed in the corresponding module number is not a DO module,

a hyphen is output.

If the module installed in the corresponding module number is a DO module, “1”

or “0” is output for the number of channels in the module in ascending order by

channel number.

“1” indicates relay (DO channel) ON state, and “0” indicates relay (DO channel)

OFF state.

2.10 ASCII Output Format