12 app, Scolorcom channel color (/mc), Szonecom waveform display zone (/mc) – Yokogawa Touch Screen GP20 User Manual
Page 39: Sscalecom scale display (/mc), Sbarcom bar graph display (/mc), Spartialcom partial expanded display (/mc), Sbandcom color scale band (/mc)

2-25
IM 04L51B01-17EN
Commands and Responses
1
2
App
SColorCom
Channel Color (/MC)
Sets the color of a communication channel.
Syntax SColorCom,p1,p2,p3,p4
p1 Channel number
p2 R value of RGB display colors (0 to 255)
p3 G value of RGB display colors (0 to 255)
P4 B value of RGB display colors (0 to 255)
Query
SColorCom[,p1]?
Example Set the communication channel 025 display
color to red.
SColorCom,025,255,0,0
Description
• For details on RGB values, see “Description” of the
SZoneCom
Waveform Display Zone (/MC)
Sets the waveform display zone of a communication
channel.
Syntax SZoneCom,p1,p2,p3
p1 Channel number
p2 Zone lower limit [%] (0 to 95)
p3 Zone upper limit [%] (5 to 100)
Query
SZoneCom[,p1]?
Example Set the waveform zone of communication
channel 025 waveform to 0% to 30%.
SZoneCom,025,0,30
SScaleCom
Scale Display (/MC)
Sets the scale display of a communication channel.
Syntax SScaleCom,p1,p2,p3
p1 Channel number
p2 Scale display position (Off, 1 to 10)
p3 Number of scale divisions (4 to 12, C10)
Query
SScaleCom[,p1]?
Example Display the communication channel 025 scale
at display position 1. Display four equally
spaced main scale marks.
SScaleCom,025,1,4
SBarCom
Bar Graph Display (/MC)
Sets the bar graph display of a communication channel.
Syntax SBarCom,p1,p2,p3
p1 Channel number
p2 Bar display base position
Lower Lower
Center Center
Upper Upper
p3 Number of scale divisions (4 to 12)
Query
SBarCom[,p1]?
Example Display the values of communication channel
025 on a bar graph with the center set as the
base position (Center). Display four equally
spaced main scale marks.
SBarCom,025,Center,4
SPartialCom
Partial Expanded Display (/MC)
Sets the partial expanded display of a communication
channel waveform.
Syntax SPartialCom,p1,p2,p3,p4
p1 Channel number
p2 Partial expanded On/Off (On, Off)
p3 Partial expanded boundary position [%] (1
to 99)
P4 Partial expanded boundary value
Query
SPartialCom[,p1]?
Example For channel 025 whose measurement range is
0 to 1.0000 V, display the measured value of
0.7500 V at the 50% position.
SPartialCom,025,On,50,7500
Description
• You cannot set this on a “Off” channel. p2 is fixed to
Off.
• If p2=Off, you cannot set p3 or subsequent
parameters.
• P2=On can be specified when the difference between
the span upper and lower limits is 2 digits or greater.
SBandCom
Color Scale Band (/MC)
Sets the color scale band of a communication channel.
Syntax SBandCom,p1,p2,p3,p4,p5,p6,p7
p1 Channel number
p2 Color scale band (Off, In, Out)
p3 R value of the color scale band RGB
colors (0 to 255)
P4 G value of the color scale band RGB
colors (0 to 255)
p5 B value of the color scale band RGB
colors (0 to 255)
p6 Upper limit of the color scale band display
(span lower limit to span upper limit)
p7 Lower limit of the color scale band display
(span lower limit to span upper limit)
Query
SBandCom[,p1]?
Example For communication channel 025, set a blue
band in the range of -0.5000 to 1.0000.
SBandCom,025,In,0,0,255,5000,10000
Description
• You cannot set this on a “Off” channel. p2 is fixed to
Off.
• If p2=Off, you cannot set p3 or subsequent
parameters.
• For details on RGB values, see “Description” of the
2.4 Setting Commands