Queries, Command names – Yokogawa Touch Screen GP20 User Manual
Page 16

2-2
IM 04L51B01-17EN
2.1 Command Transmission and GX20 Responses
Notes on Writing Commands in a Series
• Only setting commands can be written in a series.
• Queries (see the next section) cannot be written in a series.
• If there is an error in one of the commands in a series, the commands before it are
canceled, and those after it are not executed.
Example of a Command
SRangeAI,0001,VOLT,2V,OFF,-15000,18000,0;SRangeAI,0002,SKIP
Queries
Queries are used to inquire the GX/GP settings. To send a query, append a question mark to
the command name or parameter. When the GX/GP receives a query, it returns the relevant
setting as a character string in an appropriate syntax. Queries can be used on some of the
available setting and operation commands.
Command name? terminator
Command name,parameter1? terminator
Examples of Queries and Responses
Query
Example of Responses
SRangeAI?
SRangeAI,0001,VOLT,2V,OFF,–20000,20000,0
SRangeAI,0002,...............................................................
..........................................................................................
SRangeAI,0001?
SRangeAI,0001,VOLT,2V,OFF,–20000,20000,0
Command Names
A command name is a character string consisting of up to 16 alphanumeric characters. The
first character represents the command type.
Notes on Writing Commands Names
• Command names are not case sensitive.
• Spaces before the character string are ignored.