2.3 Parameters

This section describes parameters.

2.3.1 Measuring Range Parameters

AI Channel Span

Specify the span using an integer.

Example If the range is -2.0000 V to 2.0000 V and you

want to set the span lower limit to 0.5000 V and the span

upper limit to 1.8000 V, set the parameters to 5000 and

18000, respectively.

SRangeAI,0001,VOLT,2V,FF,5000,18000,0

Scaling

Scaling is possible on AI and DI channels. Scaling is

specified by a mantissa and decimal place.

Example To set the scaling to -10.00 to 20.00, set the

scaling lower limit to -1000, scaling upper limit to 2000,

and the decimal place to 2. The decimal place value

represents the number of digits to the right of the decimal

point.

Math Channel and Communication Channel

Span

Set the span of math channels and communication

channels using a mantissa and decimal place.

Example To set the span to 1.000 to 2.000, set the

scaling lower limit to 1000, scaling upper limit to 2000, and

the decimal place to 3.

2.3.2 Parameter Notation and Range

The table below shows the principle parameter notations

and ranges of values.

Type

Notation and Range of Values

AI channel

DI channel

DO channel

Specify as “unit number+module

number+channel.”

Example The AI channel whose unit

number is 0, module number is 1, and

channel number is 02 is 0102.

Math channel

GX20/GP20: 001 to 100
GX10/GP10: 001 to 050
For SGroup and SMailAlarm

commands, insert “A” in front.

Example A001

Communication

channel

GX20/GP20: 001 to 300

GX10/GP10: 001 to 050

For SGroup and SMailAlarm

commands, insert “C” in front.

Example C001

Number of

channels for

recording

display data

GX20/GP20: 001 to 500

GX10/GP10: 001 to 100

Number of

channels for

recording event

data

GX20/GP20: 001 to 500

GX10/GP10: 001 to 100

Type

Notation and Range of Values

Number of

report channels

GX20/GP20: 1 to 60

GX10/GP10: 1 to 50

Number of

display groups

GX20/GP20: 1 to 50

GX10/GP10: 1 to 30

Number of

channels

that can be

registered to

display groups

GX20/GP20: 20

GX10/GP10: 10

Modbus

command

number

GX20/GP20: 1 to 100

GX10/GP10: 1 to 50

2.3.3 Specifying a Range

When specifying consecutive channel numbers or group

numbers in a setting command, you can specify them

using a range instead of specifying each number one by

one.

• Use a hyphen to separate the first number and the last

number. For I/O channels, you can specify a range that

spans over multiple slots that modules are installed in.

• You can specify the minimum number by omitting the

number before the hyphen and the maximum number

by omitting the number after the hyphen. If you want

to specify all numbers from the first number to the last

number, specify only the hyphen.

Example 1

To specify 3 to 10: “

3-10”

To specify 3 to the maximum number: “

3-”

To specify the first number to 10: “

-10”

To specify all numbers: “

-”

Example 2

A command that sets the channel ranges of AI modules

installed in slots 0 to 2 to Skip.

SRangeAI,0001-0210,Skip or

SRangeAI,-0210,Skip

If a different module is installed in slot 1, queries will work,

but setting commands will result in error.