Yokogawa AXFA14G/C User Manual
Page 34

IM 01E20C02-01E
6-5
6. PARAMETER DESCRIPTION
T0604-2.EPS
Item
Name
Display unit
(BRAIN)
Data range
Display unit
/BRAIN
Default value
(*): Indicated item
Units
R/W
Position
of decimal
point
Description
Mass Flow Density
(MASS DENSITY)
3
Velocity Check
(VELOCITY CHK)
Density Unit
(DENSITY UNIT)
R
m/s
0.000 to 99.999
C48
0.0001 to 32000
100
0 to 4
W
User Span Select
(USER SPN SEL)
Flow User Unit
(FL USER UNIT)
Flow User Span
(FL USER SPAN)
W
C45
W
0 to 32000
W
No
Yes
kg/m
3
lb/gal
lb/cf
0 to 4
8 alphanumeric
characters
W
C48
R
—
(SELF CHECK)
C49
C60
Good
Error
Sets density when mass flow rate
is selected (with units from C45).
Sets units for density when mass
flow rate is selected.
Selects whether or not special
units are used for flow rate units.
Sets the special flow rate units.
See “6.5 Alarm Functions”.
Sets span when using special flow
rate units.
0
Display of the span setting using
flow velocity (m/s).
No
kg/m
3
C44
C46
C45
C47
(4) Item D (Menu D): Total Setting items
Menu D contains setting items such as the totalization scale and the forward/reverse totalized values.
T0605.EPS
Item
Name
Display unit
(BRAIN)
Data range
Display unit
/BRAIN
Default value
(*): Indicated item
Units
R/W
Position
of decimal
point
Description
0
Pulse/s (*)
0 to 4
0
No
Yes
0
0
0
Total Decimal Pnt
(TL DECIMAL)
Ttl Set Val Lower
(TL SET VAL L)
Total Low Cut
(TOTAL LOWCUT)
Total Execution
(TOTAL EXEC)
Ttl Set Val Upper
(TL SET VAL U)
W
Ttl Switch Lower
(TL SWITCH LO)
Total Scale
(TOTAL SCALE)
Total Set
(TOTAL SET)
Total Unit
(TOTAL UNIT)
W
0 to 99
0 to 999999
0 to 99
W
0
1
2
3
4
5
6
7
0 to 32000
Start
Stop
Preset Total
Preset Rev Total
0 to 100
0 to 999999
Ttl Switch Upper
(TL SWITCH UP)
W
W
W
W
W
%
D10
(B30)
n Unit/P
u Unit/P
m Unit/P
Unit/P
k Unit/P
M Unit/P
Pulse/s
W
W
D30
D23
D31
D24
R
D60
—
(SELF CHECK)
D11
D22
Good
Error
D13
D12
D20
D21
D10
Executes “Start” or “Stop” of the
totalization function, or executes
“Preset Total” or “Preset Rev
Total”.
Sets the totalization switch value
in the lower 6 digits of the 8-digit
totalized value.
Sets the totalization preset value
in the upper 2 digits of the 8-digit
totalized value.
Sets the range in vicinity of 0%
within which the totalization
display will be halted.
Selects position of decimal point
for totalization display
Sets the totalization preset value
in the lower 6 digits of the 8-digit
totalized value.
Sets the totalization switch value
in the upper 2 digits of the 8-
digits totalized value.
See “6.5 Alarm Functions”.
Selects whether or not special
units are used as totalized units.
Sets the special totalized units.
W
0
0
3 %
0
Start
0
No
Ttl User Select
(TL USER SEL)
Ttl User Unit
(TL USER UNIT)
8 alphanumeric
characters
D00
0
Sets the flow rate per one pulse as
used for totalization display.
Linked with B31.
0 (*)
Selects the flow rate unit per one
pulse as used for totalization
display. Linked with B30.