Installation, 1 installation location, 2 mounting – Yokogawa AXFA14G/C User Manual
Page 12: Installation -1, Installation location -1, Mounting -1
![background image](/manuals/360070/12/background.png)
IM 01E20C02-01E
3-1
3. INSTALLATION
3.
INSTALLATION
WARNING
Installation of the magnetic flowmeter must be
performed by expert engineer or skilled person-
nel. No operator shall be permitted to perform
procedures relating to installation.
3.1 Installation Location
IMPORTANT
Install the instrument in a location where it is not
exposed to direct sunlight. For ambient tempera-
ture, refer to Chapter 11 “OUTLINE”.
The instrument may be used in an ambient
humidity where the RH ranges from 0 to 100%.
However, avoid long-term continuous operation
at relative humidity above 95%.
3.2 Mounting
This instrument can be mounted on a 2-inch pipe in a
vertical or horizontal position depending on the
installation site.
᭹ Vertical Mounting
F0301.EPS
Mounting fixture
2-inch pipe
Nut
Washer
Screw
U-bolt
1. Fix the instrument on the mounting fixture using
four screws.
2. Fix the mounting fixture with the instrument
installed on a 2-inch pipe using a U-bolt.
᭹ Horizontal Mounting
F0302.EPS
2-inch pipe
Mounting fixture
Nut
Washer
Screw
U-bolt
1. Fix the instrument casing on the mounting fixture
using four screws.
2. Fix the mounting fixture with the instrument
installed on a 2-inch pipe using a U-bolt.
Figure 3.2.1
2-inch Pipe Mounting