Accessories, Gauge adapter kit, Remote pilot access plate kits – Ross Controls TURCK MODULAR I User Manual
Page 15: Size 1 auxiliary access plate kits, Interposed supply & exhaust modules, Interposed flow controls, Features

15
www.rosscontrols.com
Accessories
Included with all Size 00 Regulators. Both kits are
required on all Size 0 & 00 Regulators when the
Regulator is on the last Station on the Right (14) End.
Gauge Adapter Kit
Description
Part Number
Gauge Kit
RPS5651160P
1/8" Female to 1/8" Female Coupling
R207P-2*
1/8" Male to 1/8" Male Long Nipple
RVS215PNL-2-15*
* Included in Gauge Kit RPS5651160P
5599-1 Shown
Remote Pilot
Access Plate Kits
Size
Port
Size
Kit Number
NPT
BSPP “G”
Size 1
1/8"
RPS401500CP
RPS401501CP
Size 2
1/8"
RPS411500CP
RPS411501CP
Size 3
1/8"
RPS421500CP
RPS421501CP
Kit includes: Pilot Port Access Plate, Gasket and Mounting Studs.
Size 1
Auxiliary
Access Plate Kits
Size
Port Size
Kit Number
NPT
BSPP “G”
Size 1
1/4" & 3/8"
RPS403000CP
RPS403001CP
Kit includes: Pilot Port Access Plate, Gasket and Mounting Screws.
• Used on Size 1 Manifolds to provide auxiliary access to Ports 1, 3 & 5.
• Port 1: 1/4", Ports 3 & 5: 3/8".
Height: .72 Inch
Interposed Supply &
Exhaust Modules
Valve Size
NPT
BSPP “G”
Size 00
(15407-2)
Supply
RPS561600P
RPS561601P
Exhaust
RPS561700P
RPS561701P
Size 0
(15407-2)
Supply
RPS551600P
RPS551601P
Exhaust
RPS551700P
RPS551701P
Quantity 1
• Used on Size 00 & Size 0 valves to provide a pressure or exhaust
path to individual valves.
15407-2 Shown
Remote Pilot Access Plates, Exhaust Modules, Air Supply Bases
A Interposed Flow Control and Common Port Interposed Regulator may be
sandwiched together on a manifold or subbase. The Interposed Flow Control
MUST be located between the manifold/subbase and the Common Port
Interposed Regulator.
Interposed Flow Controls
Features
:
• Both adjustment screws are located on the 12 end of the unit.
•
Interposed Flow Control mounts with its own studs, which means the valve uses
standard bolts for mounting.
• Interposed Flow Control is not to be used as a shut off device and is not bubble
tight when needles are fully turned down.
Valve Size
Plug-In 5599-2
Size 1
RPS4035CP
Size 2
RPS4135CP
Size 3
RPS4235CP
Plug-In 5599-2
Size 2 Shown