Warner Electric SFC-120, SFC-170, SFC-250, SFC-400 Bearing Mounted, Flange Mounted User Manual
Page 43

1B
1A-1
1A
1A-3
1A-2
2-1
2-2
2-3
2
(Shipped Assembled)
2-2
2-4
2-5
2-4-1
How to Order:
1. Specify Type of Armature Desired.
2. Specify Bore Size for Item 1A-1 or 1B and Item 2.
3. Specify Voltage for Item 2.
Example:
SFC-250 Clutch Coupling per I-25523 - 90 Volt
Standard Armature
1/2" Armature Hub Bore
1/2" Rotor Bore
These units meet standards set forth in UL508 and are
listed under guide card #NMTR2, file #59164. These
units are CSA certified under file #LR11543.
Item
Description
Part Number
Qty.
1A
Armature and Hub
1A-1
Armature Hub
1
3/8" Bore
5103-541-002
1/2" Bore
5103-541-004
5/8" Bore
5103-541-006
3/4" Bore
5103-541-008
1A-2
Armature
5124-111-001
1
1A-3
Release Spring
5103-101-003
1
1B
Antibacklash Armature
1
3/8" Bore
5365-111-003
1/2" Bore
5365-111-005
5/8" Bore
5365-111-007
3/4" Bore
5365-111-009
2
Field and Rotor Assembly
1
6 Volt – 3/8" Bore
5103-452-002
24 Volt – 3/8" Bore
5103-452-004
90 Volt – 3/8" Bore
5103-452-007
6 Volt – 1/2" Bore
5103-452-016
24 Volt – 1/2" Bore
5103-452-018
90 Volt – 1/2" Bore
5103-452-021
2-1
Rotor
1
3/8" Bore
5103-751-014
1/2" Bore
5103-751-016
2-2
Retainer Ring
748-0371
2
2-3
Ball Bearing
166-0108
1
2-4
Field
1
Item
Description
Part Number
Qty.
6 Volt
5103-451-018
24 Volt
5103-451-020
90 Volt
5103-451-023
2-4-1 Terminal Accessory
5103-101-002
1
2-5
Set Collar*
266-0005
1
*Used with 1/2" Bore only.
SFC-250 Clutch Coupling Bearing Mounted
Drawing I-25523
43
Warner Electric • 800-825-9050
P-200