Warner Electric SFC-120, SFC-170, SFC-250, SFC-400 Bearing Mounted, Flange Mounted User Manual
Page 15
1B
1A-1
1A-2
1A
2
4
3
SF-120 Clutch Flange Mounted – Outside Mounted
Drawing I-25508
Item
Description
Part Number
Qty.
1A
Armature and Hub
1A-1
Armature Hub
1
3/16" Bore
5602-541-009
1/4" Bore
5602-541-008
1A-2
Armature
110-0110
1
1B
Antibacklash Armature
1
3/16" Bore
5602-111-002
1/4" Bore
5602-111-003
5/16" Bore
5602-111-007
2
Rotor
1
3/16" Bore
5602-751-004
1/4" Bore
5602-751-002
5/16" Bore
5602-751-003
3
Mounting Accessory
5101-101-001
1
4
Field
1
6 Volt
5602-451-003
24 Volt
5602-451-005
90 Volt
5602-451-007
How to Order:
1. Specify Type of Armature Desired.
2. Specify Bore Size for Item 1A-1 or 1B and Item 2.
3. Specify Voltage for Item 4.
Example:
SF-120 Clutch per I-25508 - 90 Volt
Standard Armature
1/4" Armature Hub Bore
1/4" Rotor Bore
These units meet standards set forth in UL508 and are
listed under guide card #NMTR2, file #59164.
These units are CSA certified under file #LR11543.
15
Warner Electric • 800-825-9050
P-200
• 819-0481