SF-120 Clutch Flange Mounted

Customer Shall Maintain:
1. Squareness of field mounting face with shaft with

.003 T.I.R. measured at pilot diameter.

2. Concentricity of field mounting pilot diameter with

rotor mounting shaft within .003 T.I.R.

Armature Shaft

.187 – .250

Rotor Shaft

.187 – .312

Static Torque

5 lb. in.

Maximum Speed

3,600 rpm

Standard Voltage

D.C. 6, 24, 90

All dimensions are nominal unless otherwise noted.

Bore Dimensions

Rotor

Armature

Bore Dia.

Bore Dia.

.188/.187

.195/.190

.251/.250

.257/.252

.313/.312

Armature View

For Bore sizes see

chart below.

For Bore sizes see

chart below.

Field View

45°

.130/.123 dia.

4 holes equally

spaced on 1.312

dia. B.C.*

1.499/1.497

Pilot Dia.

* Mounting holes are within .006 of true position relative to pilot diameter.

.502

.500

.515

.511

Std. Arm

.072 (Std.)

.072 (Anti.)

.035/.004 (Std.)

.020/.008 (Anti.)

When New

12

.156

.062

.109

.019

.000

.065/.062 dia.

2 holes equally

spaced

#4-40

UNC-3A

.187

Max.

*

.020

.000

.546

1.171 Max.

.375

(Std.)

.375

(Anti.)

.528

.375

(Std.)

.375

(Anti.)

.625

Antibacklash Arm

.072 (Std.)

.072 (Anti.)

.031

1.234

Max. Dia.

Std. Arm.

Antibacklash Arm.

This manual is related to the following products: