How to Order:
1. Specify Type of Armature Desired.
2. Specify Bore Size for Item 1A-1 or 1-B and Item 2.
3. Specify Voltage for Item 3.
Example:
SFC-250 Clutch Coupling per I-25522 - 90 Volt
Standard Armature
1/2" Armature Hub Bore
1/2" Rotor Bore
These units meet standards set forth in UL508 and are
listed under guide card #NMTR2, file #59164.
These units are CSA certified under file #LR11543.
1A-1
1A-3
1A
1A-2
2
4
3
3-1
1B
Item
Description
Part Number
Qty.
1A
Armature and Hub
1A-1
Armature Hub
1
3/8" Bore
5103-541-002
1/2" Bore
5103-541-004
5/8" Bore
5103-541-006
3/4" Bore
5103-541-008
1A-2
Armature
5124-111-001
1
1A-3
Release Spring
5103-101-003
1
1B
Antibacklash Armature
1
3/8" Bore
5365-111-003
1/2" Bore
5365-111-005
5/8" Bore
5365-111-007
3/4" Bore
5365-111-009
2
Rotor
1
3/8" Bore
5103-751-008
1/2" Bore
5103-751-010
3
Field
1
6 Volt
5103-451-002
24 Volt
5103-451-004
90 Volt
5103-451-007
3-1
Terminal Accessory
5103-101-002
1
4
Mounting Accessory
5102-101-001
1
SFC-250 Clutch Coupling Flange Mounted Outside Mounted
Drawing I-25522
39
Warner Electric • 800-825-9050
P-200