beautypg.com

Vestil SWA-60-AW User Manual

Page 49

background image

F:\Manual\SM-1517R-110V-100514

14.05.2010.

- 47 -

11-1-2 There isn’t DC12 Volt. on power supply PD-25A

Refer to PC board KS-050201-MB, check

if there’s DC12V at P3 and P4 on CN1.

YES

Replace connection cord CN11

NO

Refer to PC board PD-25A, check if there’s

DC12V at P3 and P4 on CN2.

YES

Replace connection cord CN1.

NO

Check if FUSE F1 on PC board PD-25A is

blown.

YES

Replace FUSE.

NO

Refer to PC board PD-25A, check if there’s

AC220V at P1 and P2 on CN1.

YES

Replace PC board PD-25A.

NO

Check if there’s AC110V at terminal L12

and L22.

YES

Replace FUSE F3 and F4(3A).

NO

Check if there’s AC110V at terminal L11

and L21.

YES

Replace Line Filter.

NO

Check if input power voltage is normal.

YES

Replace Main Power Switch.